{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDND616","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDND616","canonicalUrl":"https://aoctrl.com/schneider/A9TDND616","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDND616","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active iCV40 ARC arc-fault detection device, A9TDND616, 1P+N, 16 A rated, C-curve, 10 kA breaking capacity at 230 V AC, clip-on DIN rail mount.","salesMarkdown":"## Arc-fault detection device for final circuits Rated 16 A with a C-curve trip characteristic, it interrupts fault currents up to 10 kA at 230 V AC, 50 Hz, complying with EN/IEC 62606 and EN/IEC 61009-1/2-1. The white (RAL 9003) housing and top/bottom cable entry keep panel wiring clean and consistent. Measurement accuracy of ±2 % for voltage and current, ±5 % for power, and the ability to log voltage, active power, current, and power factor make this unit suitable for energy monitoring or fault-event diagnostics — not just protection. The local signalling (ON, OFF, fault trip LED, arc fault diagnostic) gives a visual status without needing to open the panel door. Electrical durability of 20,000 cycles at rated load and mechanical durability of 20,000 cycles align with typical residential/commercial switching duty — expect the unit to outlast the building's fit-out cycle under normal use. Mounts on DIN rail via the clip-on mechanism. Tightening torque for the terminals is 2 N·m; wire stripping length is 14 mm. Tropicalisation severity B (28-day damp heat test per IEC 60068-2-30) means it handles high-humidity environments without derating. Total power losses of 3.408 W (2.65 W per pole) are low enough that no special ventilation is needed in a standard enclosure. The 73 mm depth fits flush in shallow consumer units.","metaTitle":"Schneider Electric A9TDND616 Acti9 iCV40 ARC, 16 A C-Curve,","metaDescription":"Schneider Electric A9TDND616 Acti9 Active iCV40 ARC arc-fault detection device. 16 A rated, C-curve, 10 kA breaking capacity at 230 V AC. Clip-on DIN rail. Current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 Active iCV40 ARC","Mounting mode":"Clip-on","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Earth leakage Overload","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Targeted country":"India","Breaking capacity":"10000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40H ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"3.408 W","[In] rated current":"16 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"2.65 W","Wire stripping length":"14 mm","Breaking capacity code":"H","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Power losses on neutral":"0.763 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Active arc fault detection RCBO","Suitability for isolation":"Yes","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"7500 A AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9TDND616/active-arc-fault-detection-rcbo-acti9-active-icv40h-arc-1p+n-16a-c-curve-30ma-type-asi-10000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDND616/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9TDND616?","answer":"The A9TDND616 has a breaking capacity of 10,000 A Icn at 230 V AC, 50 Hz, conforming to EN/IEC 61009-2-1. The 'H' code indicates the higher interrupting rating within the iCV40 family."},{"question":"What standards does the A9TDND616 comply with?","answer":"It complies with EN/IEC 62606 (arc-fault detection devices), EN/IEC 61009-1 (residual current operated circuit-breakers with integral overcurrent protection), and EN/IEC 61009-2-1 (applicability of the general rules to RCBOs functionally independent of line voltage)."},{"question":"What is the depth of the A9TDND616?","answer":"The depth is 73 mm, which fits flush in standard shallow consumer units and distribution boards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDND616","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDND616 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}