{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TYA4240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TYA4240","canonicalUrl":"https://aoctrl.com/schneider/A9TYA4240","factsUrl":"https://aoctrl.com/api/mcp/products/A9TYA4240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 VigiARC iC60, arc-fault detection with residual current protection add-on block, 2P, 40 A, 30 mA, 230 V AC, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9TYA4240 is an Acti9 VigiARC iC60 arc-fault detection device (AFDD) combined with a 30 mA residual current device (RCD) in a single add-on block, 2-pole, rated 40 A at 230 V AC. The 40 A [In] and 30 mA sensitivity cover typical final circuits supplying socket outlets or fixed equipment in residential and light commercial installations. The Type A-SI (Super Immunised) earth-leakage class means it resists nuisance tripping from high-frequency leakage or pulsed DC waveforms common on modern electronics. Rated impulse withstand voltage is 4 kV (Uimp), insulation voltage 400 V AC (Ui), and pollution degree 2 — suitable for standard indoor panel environments. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, with tropicalisation severity B per IEC 60068-2-30 for 28 days. Neutral is on the left. Local signalling includes ON/OFF status, a fault-trip LED, and an arc-fault diagnostic indicator. Electrical durability: 10,000 cycles above 25 A, 20,000 cycles at or below 25 A; mechanical durability 20,000 cycles. The device records date/time of events and maintenance indicators.","metaTitle":"Schneider Electric A9TYA4240 Acti9 VigiARC iC60, 40 A, 30 mA","metaDescription":"Schneider Electric A9TYA4240 Acti9 VigiARC iC60 arc-fault detection device with 30 mA residual current protection, 40 A rated current, 2-pole, 230 V AC, DIN rail mount, current lif","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Width":"54 mm","title":"A9TYA4240","Colour":"White (RAL 9003)","Height":"91 mm","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Arc fault detection with residual current protection add-on block, Acti9 VigiARC iC60, 2P, 40A, 30mA, type A-SI","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 VigiARC iC60","Mounting mode":"Clip-on","Quality labels":"NF","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Range of product":"Acti9","Device short name":"VigiARC iC60","Network frequency":"50 Hz","Poles description":"2P","Tightening torque":"2 N.m","Operating altitude":"2000 m","[In] rated current":"40 A","Electrical durability":"10000 cycles > 25 A 20000 cycles <= 25 A","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","IP degree of protection":"IP20 conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Product or component type":"Arc fault detection with residual current protection add-on block","Threshold tripping voltage":"275 V for +/- 5 V","[Ui] rated insulation voltage":"400 V AC","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$329.99","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/80dcbaaae84c96e78f6c2aed8beb12ee.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9TYA4240/arc-fault-detection-with-residual-current-protection-addon-block-acti9-vigiarc-ic60-2p-40a-30ma-type-asi/"},"ai":{"faq":[{"question":"What standards does A9TYA4240 comply with?","answer":"It complies with EN/IEC 62606 (arc-fault detection devices), EN/IEC 61009-1, and EN/IEC 61009-2-1 (RCBOs). It also carries NF quality label."},{"question":"What is the rated current and earth-leakage sensitivity of A9TYA4240?","answer":"Rated current [In] is 40 A, earth-leakage sensitivity is 30 mA, Type A-SI (Super Immunised), instantaneous time delay."},{"question":"Where can I buy A9TYA4240 and how is it quoted?","answer":"This part is sourced through independent distribution channels. It is quoted to order against an RFQ; availability and current pricing are confirmed at quote time."},{"question":"What is the mounting and dimensions of A9TYA4240?","answer":"Clip-on DIN rail mounting, 2 x 9 mm pitches width (18 mm), depth 73 mm, height 91 mm. Neutral left position."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TYA4240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TYA4240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}