{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TYAE240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TYAE240","canonicalUrl":"https://aoctrl.com/schneider/A9TYAE240","factsUrl":"https://aoctrl.com/api/mcp/products/A9TYAE240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 VigiARC iC60, active arc fault detection with residual current protection add-on block, 40 A, 30 mA, 2P, 230 V AC, DIN rail mount.","salesMarkdown":"It combines two protection functions in one DIN-rail module: series arc fault detection per EN/IEC 62606 and residual current protection per EN/IEC 61009-1 and EN/IEC 61009-2-1, with a rated current of 40 A and an earth-leakage sensitivity of 30 mA (Type A-SI, Super Immunised). The 30 mA sensitivity means it trips on ground faults that could harm personnel, while the Super Immunised designation prevents nuisance trips from high-frequency inverter noise or transient surges common on modern industrial lines. The overvoltage trip threshold is set at 275 V ±5 V, protecting downstream equipment from sustained voltage swells. Measurement accuracy is ±2 % for voltage and current, ±5 % for active power, which is sufficient for energy monitoring and fault logging via the compatible EcoStruxure Panel Server concentrators. Clip-on mounting on DIN rail, occupying 2 x 9 mm pitches. Neutral is on the left. Operating altitude is rated to 2000 m; storage temperature range is -40 to 85 °C with tropicalisation severity B per IEC 60068-2-30 for 28 days, meaning it handles humidity cycling in non-condensing panel environments. Local signalling includes ON, OFF, and fault-trip LED indicators plus an arc fault diagnostic LED. Event management covers overvoltage, earth leakage, and overload events with date-and-time recording and maintenance indicators. This is an outgoer device — intended for final subcircuit protection, not incoming main switch duty.","metaTitle":"Schneider Electric A9TYAE240 Acti9 VigiARC iC60, 40 A, 30 mA","metaDescription":"Schneider Electric A9TYAE240 Acti9 VigiARC iC60 active arc fault detection with residual current protection add-on block. 40 A rated current, 30 mA earth leakage sensitivity, 2P, 2","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Width":"54 mm","title":"A9TYAE240","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Active arc fault detection with residual current protection add-on block, Acti9 Active VigiARC iC60, 2P, 40A, 30mA, type A-SI","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 Active VigiARC iC60","Mounting mode":"Clip-on","Quality labels":"NF","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Overvoltage Earth leakage Overload","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Range of product":"Acti9","Device short name":"VigiARC iC60","Network frequency":"50 Hz","Poles description":"2P","Tightening torque":"2 N.m","Operating altitude":"2000 m","[In] rated current":"40 A","Type of measurement":"Voltage Active power Current Power factor","Electrical durability":"10000 cycles > 25 A 20000 cycles <= 25 A","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","IP degree of protection":"IP20 conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Product or component type":"Active arc fault detection with residual current protection add-on block","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Threshold tripping voltage":"275 V for +/- 5 V","[Ui] rated insulation voltage":"400 V AC","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$395.87","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e8ed2b77d55a1030a7349e81f29b80f.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9TYAE240/active-arc-fault-detection-with-residual-current-protection-addon-block-acti9-active-vigiarc-ic60-2p-40a-30ma-type-asi/"},"ai":{"faq":[{"question":"What are the key ratings of the A9TYAE240?","answer":"Rated current 40 A, earth-leakage sensitivity 30 mA Type A-SI, overvoltage trip at 275 V ±5 V, operational voltage 230 V AC at 50 Hz, insulation voltage 400 V AC."},{"question":"What standards does the A9TYAE240 comply with?","answer":"It complies with EN/IEC 62606 (arc fault detection), EN/IEC 61009-1 (residual current operated circuit-breakers), and EN/IEC 61009-2-1 (applicability of the general rules to RCBOs). It carries the NF quality label."},{"question":"Where can I buy the A9TYAE240 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TYAE240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TYAE240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}