{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TYAE240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TYAE240","canonicalUrl":"https://aoctrl.com/schneider/A9TYAE240","factsUrl":"https://aoctrl.com/api/mcp/products/A9TYAE240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 VigiARC iC60, active arc fault detection with residual current protection add-on block, 40 A, 30 mA, 2P, 230 V AC, DIN rail mount.","salesMarkdown":"It combines two protection functions in one DIN-rail module: series arc fault detection per EN/IEC 62606 and residual current protection per EN/IEC 61009-1 and EN/IEC 61009-2-1, with a rated current of 40 A and an earth-leakage sensitivity of 30 mA (Type A-SI, Super Immunised). The 30 mA sensitivity means it trips on ground faults that could harm personnel, while the Super Immunised designation prevents nuisance trips from high-frequency inverter noise or transient surges common on modern industrial lines. The overvoltage trip threshold is set at 275 V ±5 V, protecting downstream equipment from sustained voltage swells. Measurement accuracy is ±2 % for voltage and current, ±5 % for active power, which is sufficient for energy monitoring and fault logging via the compatible EcoStruxure Panel Server concentrators. Clip-on mounting on DIN rail, occupying 2 x 9 mm pitches. Neutral is on the left. Operating altitude is rated to 2000 m; storage temperature range is -40 to 85 °C with tropicalisation severity B per IEC 60068-2-30 for 28 days, meaning it handles humidity cycling in non-condensing panel environments. Local signalling includes ON, OFF, and fault-trip LED indicators plus an arc fault diagnostic LED. Event management covers overvoltage, earth leakage, and overload events with date-and-time recording and maintenance indicators. This is an outgoer device — intended for final subcircuit protection, not incoming main switch duty.","metaTitle":"Schneider Electric A9TYAE240 Acti9 VigiARC iC60, 40 A, 30 mA","metaDescription":"Schneider Electric A9TYAE240 Acti9 VigiARC iC60 active arc fault detection with residual current protection add-on block. 40 A rated current, 30 mA earth leakage sensitivity, 2P, 2","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White (RAL 9003)","Depth":"73 mm","Width":"54 mm","Height":"91 mm","Voltage":"230 V AC","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","IP Rating":"IP20","Product Status":"Active","Pollution Degree":"2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"400 V AC","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Electrical Life Cycles":"10000 cycles > 25 A 20000 cycles <= 25 A","Mechanical Life Cycles":"20000 cycles","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$395.87","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e8ed2b77d55a1030a7349e81f29b80f.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9TYAE240/active-arc-fault-detection-with-residual-current-protection-addon-block-acti9-active-vigiarc-ic60-2p-40a-30ma-type-asi/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TYAE240/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TYAE240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TYAE240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}