{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TYB4240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TYB4240","canonicalUrl":"https://aoctrl.com/schneider/A9TYB4240","factsUrl":"https://aoctrl.com/api/mcp/products/A9TYB4240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 VigiARC iC60 arc fault detection with residual current protection add-on block, 2P, 40 A, 30 mA, 230 V AC, DIN rail clip-on, IP20.","salesMarkdown":"It combines two protection functions in one DIN-rail module: 40 A overcurrent protection and 30 mA earth leakage, plus series arc-fault detection. Rated for 230 V AC, 50 Hz networks, 2 poles, neutral left. The 40 A rated current ([In]) sets the continuous load capacity — sized for a final subcircuit feeding lighting, socket outlets, or small equipment up to that ampacity. The 30 mA earth-leakage sensitivity is the standard threshold for personal protection against indirect contact in residential and commercial final circuits. The residual current trip is instantaneous and voltage-independent, meaning it operates regardless of supply voltage — a reliability advantage over electronic RCDs that need line power to trip. The arc-fault detection meets EN/IEC 62606, the standard for AFDDs. It monitors the waveform for the high-frequency signature of a series arc (a loose connection or damaged conductor) and trips before the arc can start a fire. The device also complies with EN/IEC 61009-1 and 61009-2-1 for RCBOs. Pollution degree 2 covers normal indoor environments with non-conductive contamination. Clip-on mounting to a standard DIN rail. The module occupies 2 x 9 mm pitches — 18 mm total width. Neutral is on the left. Tropicalisation severity B per IEC 60068-2-30 for 28 days — handles high-humidity climates. IMQ quality label marks it for the Italian market. Maximum operating altitude 2000 m. Electrical durability: 10,000 cycles above 25 A, 20,000 cycles at or below 25 A. Mechanical durability: 20,000 cycles. Current-production part — no end-of-life notice on record. Sourced through independent distribution channels. Submit an RFQ for current pricing and lead time; availability confirmed at quote time.","metaTitle":"Schneider Electric A9TYB4240 Acti9 VigiARC iC60, 40A 30mA AF","metaDescription":"Schneider Electric A9TYB4240 Acti9 VigiARC iC60 arc fault detection device with 30 mA residual current protection. 40 A, 2P, 230 V AC, DIN rail mount. EN/IEC 62606. Current product","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Width":"54 mm","title":"A9TYB4240","Colour":"White (RAL 9003)","Height":"91 mm","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Arc fault detection with residual current protection add-on block, Acti9 VigiARC iC60, 2P, 40A, 30mA, type A-SI","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 VigiARC iC60","Mounting mode":"Clip-on","Quality labels":"IMQ","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Range of product":"Acti9","Device short name":"VigiARC iC60","Network frequency":"50 Hz","Poles description":"2P","Tightening torque":"2 N.m","Operating altitude":"2000 m","[In] rated current":"40 A","Electrical durability":"10000 cycles > 25 A 20000 cycles <= 25 A","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals1...10 mm² flexible Tunnel type terminals1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Product or component type":"Arc fault detection with residual current protection add-on block","Threshold tripping voltage":"275 V for +/- 5 V","[Ui] rated insulation voltage":"250 V AC","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$329.99","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6948838712c544fb303ad9b74050c83d.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9TYB4240/arc-fault-detection-with-residual-current-protection-addon-block-acti9-vigiarc-ic60-2p-40a-30ma-type-asi/"},"ai":{"faq":[{"question":"What standards does A9TYB4240 comply with?","answer":"It complies with EN/IEC 62606 (arc-fault detection device standard), EN/IEC 61009-1, and EN/IEC 61009-2-1. It carries the IMQ quality label and is tropicalised per IEC 60068-2-30 severity B."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TYB4240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TYB4240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}