{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TYBE225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TYBE225","canonicalUrl":"https://aoctrl.com/schneider/A9TYBE225","factsUrl":"https://aoctrl.com/api/mcp/products/A9TYBE225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active VigiARC iC60, arc fault detection with residual current protection add-on block, 2P, 25 A, 30 mA, 230 V AC, clip-on DIN rail.","salesMarkdown":"It monitors for series and parallel arcing faults per EN/IEC 62606 while providing 30 mA earth-leakage protection per EN/IEC 61009-1 and -2-1. The unit integrates overvoltage, earth-leakage, and overload event management with local signalling via ON/OFF/fault-trip LED and an arc-fault diagnostic indicator. Rated at 25 A (In) on a 230 V AC, 50 Hz network, this device is sized for a final subcircuit supplying a single branch — lighting, socket outlets, or fixed equipment within that current envelope. The 30 mA earth-leakage sensitivity (Type A-SI, Super Immunised) makes it suitable for circuits where nuisance tripping from high-frequency leakage or pulsed DC fault currents is a concern; the SI designation indicates a higher immunity to transient surges than standard Type A. The overvoltage trip threshold is set at 275 V ±5 V, which protects downstream equipment if a neutral loss or supply swell pushes the phase voltage above that level. Measurement accuracy is ±2 % for voltage and current, ±5 % for active power — adequate for energy monitoring and fault logging via the EcoStruxure Panel Server concentrators (Entry, Advanced, or Universal). Electrical durability is rated at 20,000 cycles at or below 25 A, and 10,000 cycles above 25 A; mechanical durability is 20,000 cycles. These figures govern the expected service life under normal switching duty — not fault interruption, which is covered by the short-circuit breaking capacity of the upstream MCB. Neutral is on the left. Tunnel-type terminals accept 1–10 mm² flexible or 1–16 mm² rigid conductors; tighten to 2 N·m with a 14 mm strip length. IP20 rated — suitable for dry indoor enclosures only. Compliant with EN/IEC 62606 (arc fault detection devices), EN/IEC 61009-1 (RCBOs general rules), and EN/IEC 61009-2-1 (RCBOs functional independence). Carries the IMQ quality mark. Tropicalisation severity B per IEC 60068-2-30 for 28 days. Pollution degree 2. Operating altitude limited to 2000 m.","metaTitle":"Schneider Electric A9TYBE225 Acti9 VigiARC iC60, 25A 30mA AF","metaDescription":"Schneider Electric A9TYBE225 Acti9 VigiARC iC60 arc fault detection device with 30mA earth leakage, 25A rated current, 230V AC. Active production. Sourced to order. Standards EN/IE","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Width":"54 mm","title":"A9TYBE225","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Active arc fault detection with residual current protection add-on block, Acti9 Active VigiARC iC60, 2P, 25A, 30mA, type A-SI","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 Active VigiARC iC60","Mounting mode":"Clip-on","Quality labels":"IMQ","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Overvoltage Earth leakage Overload","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Range of product":"Acti9","Device short name":"VigiARC iC60","Network frequency":"50 Hz","Poles description":"2P","Tightening torque":"2 N.m","Operating altitude":"2000 m","[In] rated current":"25 A","Type of measurement":"Voltage Active power Current Power factor","Electrical durability":"10000 cycles > 25 A 20000 cycles <= 25 A","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals1...10 mm² flexible Tunnel type terminals1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Product or component type":"Active arc fault detection with residual current protection add-on block","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Threshold tripping voltage":"275 V for +/- 5 V","[Ui] rated insulation voltage":"250 V AC","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$395.87","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ecedbac01a93c3dc83a8dec4294f6fd8.pdf","sourceUrl":"https://www.se.com/ae/en/product/A9TYBE225/active-arc-fault-detection-with-residual-current-protection-addon-block-acti9-active-vigiarc-ic60-2p-25a-30ma-type-asi/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9TYBE225?","answer":"Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is A9TYBE225's listed depth?","answer":"The depth is 73 mm."},{"question":"What is A9TYBE225's listed width?","answer":"The width is 54 mm, occupying 2 modules of 9 mm pitch on a DIN rail."},{"question":"What compliance documentation does Schneider provide for A9TYBE225?","answer":"The device is certified to EN/IEC 62606, EN/IEC 61009-1, and EN/IEC 61009-2-1, and carries the IMQ quality mark. Tropicalisation per IEC 60068-2-30 severity B is also documented."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TYBE225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TYBE225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}