{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V00625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V00625","canonicalUrl":"https://aoctrl.com/schneider/A9V00625","factsUrl":"https://aoctrl.com/api/mcp/products/A9V00625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 1P+N, 25 A rated, 10 mA sensitivity, Type A, voltage-independent, clip-on DIN rail mount.","salesMarkdown":"It's a 1P+N unit rated at 25 A with a 10 mA trip sensitivity, Type A (pulsating DC and AC sinusoidal earth leakage). The voltage-independent tripping technology means it detects leakage and disconnects even if the phase voltage is lost — no auxiliary supply needed. The 10 mA sensitivity is the standout here — that's a high-sensitivity trip threshold, typically specified for circuits where direct contact with live parts is a credible risk (e.g., socket outlets in bathrooms, construction sites, or medical locations per IEC 60364). The 25 A rated current (In) matches standard final-circuit loads like lighting, general-purpose socket rings, or small appliances on a 240 V AC single-phase network. Type A protection covers both sinusoidal AC leakage and pulsating DC leakage from rectified loads — think electronics, LED drivers, or variable-speed appliances downstream. The voltage-independent trip mechanism is a reliability advantage: it doesn't rely on the mains voltage to operate, so a lost neutral or phase doesn't defeat the protection. Bottom tunnel terminals accept 1…25 mm² rigid or 1…16 mm² flexible cable, with a 14 mm strip length and 2 N·m tightening torque. It's compatible with bottom-entry comb busbars. The IP20 enclosure is standard for distribution boards; the IP40 rating applies when enclosed in a modular enclosure. The trip indicator gives local visual signalling of a residual current trip. Designed and certified to IEC 61009-1 and EN 61009-1 (the harmonized standard for RCBOs and RCCBs with overcurrent protection integration). The insulation voltage (Ui) is rated 500 V AC, impulse withstand (Uimp) is 6 kV per IEC 60947-2, and pollution degree 3 per IEC 60947-2 — suitable for industrial environments where conductive pollution is present. The 8/20 µs impulse withstand of 250 A per IEC 61009-1 confirms it handles surge currents without nuisance tripping.","metaTitle":"Schneider Electric A9V00625 Acti9 Vigi iC60 RCD, 1P+N, 25A,","metaDescription":"Schneider Electric A9V00625 Acti9 Vigi iC60 add-on RCD. 1P+N, 25A rated, 10mA sensitivity, Type A, voltage-independent. Active production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"54 mm","Height":"91 mm","Standards":"IEC 61009-1 EN 61009-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"1P + N","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"10 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"240 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/be6f55d4f8d9409b0dba3db146d7f8c1.pdf","sourceUrl":"https://www.se.com/uk/en/product/A9V00625/vigi-ic60-earth-leakage-addon-block-1p-+-n-25a-10ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V00625/alternatives.json"},"ai":{"faq":[{"question":"What is the A9V00625 used for?","answer":"It is an add-on residual current device (RCD) for the Acti9 iC60 MCB range, providing 10 mA Type A earth leakage protection on a 25 A, 1P+N circuit at 240 V AC."},{"question":"Where can I buy the A9V00625?","answer":"The A9V00625 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does the A9V00625 comply with?","answer":"It complies with IEC 61009-1 and EN 61009-1, with impulse withstand of 6 kV per IEC 60947-2 and pollution degree 3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V00625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V00625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}