{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V01240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V01240","canonicalUrl":"https://aoctrl.com/schneider/A9V01240","factsUrl":"https://aoctrl.com/api/mcp/products/A9V01240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V01240, 2P, 40 A, 30 mA sensitivity, Type AC, voltage-independent tripping.","salesMarkdown":"The Schneider Electric A9V01240 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to clip onto the outgoing side of an iC60 MCB. It provides earth-leakage protection for a 2-pole circuit, rated at 40 A with a 30 mA sensitivity, Type AC (sinusoidal AC residual currents only). The unit is voltage-independent — the tripping mechanism does not rely on the line voltage to detect a fault, which means it remains functional even if the neutral is lost upstream. The 40 A rated current (In) sets the continuous load this RCD can carry — sized for a 40 A feeder or submain, not for a final subcircuit below that rating. The 30 mA sensitivity is the standard for personal protection against indirect contact in most residential and commercial installations per IEC 60364. The voltage-independent tripping technology is a differentiator: the RCD stores enough energy from the fault current itself to trip the mechanism, so a lost neutral or a voltage sag on the supply side does not disable protection. This is standard for most electromechanical RCDs but worth confirming if the specification calls for it explicitly. Clip-on mounting to DIN rail (EN/IEC 60715). The unit occupies 4 modules of 9 mm pitch (72 mm total width). It is an add-on block that screws directly to the outgoing side of an iC60 MCB — the electrical connection is made via screws, not busbars, so the assembly forms a single combined RCBO-like unit. IP20 on the device body, IP40 when enclosed in a modular enclosure per IEC 60529. The 8/20 µs impulse withstand rating of 250 A per IEC 61009-1 confirms the device can survive common surge currents without nuisance tripping.","metaTitle":"Schneider Electric A9V01240 Vigi iC60, 40A 30mA AC Type RCD","metaDescription":"Schneider Electric A9V01240 Vigi iC60 add-on RCD block, 2P, 40A rated, 30mA sensitivity, Type AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"72 mm","Height":"91 mm","Voltage":"110...130 V AC 50/60 Hz conforming to EN/IEC 61009-1 110...130 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e4f3ea8e49d6b686c427af0c8b82aca9.pdf","sourceUrl":"https://www.se.com/ae/en/product/A9V01240/vigi-ic60-earth-leakage-addon-block-2p-40a-30ma-ac-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V01240/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V01240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V01240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}