{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V04240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V04240","canonicalUrl":"https://aoctrl.com/schneider/A9V04240","factsUrl":"https://aoctrl.com/api/mcp/products/A9V04240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V04240, 2P, 40 A, 300 mA sensitivity, Type AC, clip-on DIN rail mount.","salesMarkdown":"Rated 40 A with 300 mA sensitivity, Type AC (sinusoidal AC fault currents only). Two-pole, instantaneous trip, no time delay. Clip-on mount to DIN rail, 4 x 9 mm pitches wide (72 mm). Depth 73.5 mm, height 91 mm. Tightening torque 3.5 N.m. IP20 on the device body; IP40 inside a modular enclosure. Pollution degree 3 per IEC 60947-2. ## Electrical ratings and standards Rated operational voltage 130 V AC at 50/60 Hz per EN/IEC 61009-1 and 61009-2-1. Insulation voltage 500 V AC. Impulse withstand voltage 6 kV (Uimp). Withstands 8/20 µs impulse current of 250 A per IEC 61009-1. Voltage-independent tripping, so it operates without an external power supply.","metaTitle":"Schneider Electric A9V04240 Vigi iC60 Earth Leakage Add-on B","metaDescription":"Schneider Electric A9V04240 Vigi iC60 add-on residual current device, 2P, 40A, 300mA sensitivity, Type AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"72 mm","title":"A9V04240","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Vigi iC60 - earth leakage add-on block - 2P - 40A - 300mA - AC type","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m bottom","[In] rated current":"40 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"130 V AC 50/60 Hz conforming to EN/IEC 61009-1 130 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/735c607d3decdfd48f9acde900708b80.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9V04240/vigi-ic60-earth-leakage-addon-block-2p-40a-300ma-ac-type/"},"ai":{"faq":[{"question":"What is A9V04240 used for?","answer":"The A9V04240 is an add-on residual current device (RCD) that mounts to an Acti9 iC60 MCB to provide earth leakage protection for outgoing circuits. It is used in distribution panels for residential, commercial, and light industrial AC networks."},{"question":"What are the key ratings of A9V04240?","answer":"40 A rated current, 300 mA earth leakage sensitivity, Type AC (sinusoidal AC only), 2 poles, instantaneous trip, voltage-independent operation, rated operational voltage 130 V AC."},{"question":"Where can I buy A9V04240?","answer":"The A9V04240 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for A9V04240?","answer":"The A9V04240 complies with EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. It carries IP20 and IP40 (modular enclosure) ratings per IEC 60529, and pollution degree 3 per IEC 60947-2. Specific RoHS/REACH/UL documentation is available upon request through the distributor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V04240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V04240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}