{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V07263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V07263","canonicalUrl":"https://aoctrl.com/schneider/A9V07263","factsUrl":"https://aoctrl.com/api/mcp/products/A9V07263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V07263, 2P, 63 A, 30 mA, Type A, instantaneous, 400…415 V AC.","salesMarkdown":"The Schneider Electric A9V07263 is a Vigi iC60 add-on residual current device from the Acti9 range. It clips onto the side of an iC60 MCB to add earth-leakage protection — 2 poles, rated 63 A continuous, with 30 mA sensitivity and Type A detection for pulsating DC fault currents. The unit is voltage-independent, meaning it trips on leakage alone without needing a separate power supply to the electronics. Mounts via clip-on onto DIN rail, side-by-side with the companion iC60 MCB. The assembly takes 4 module pitches (9 mm each) — 72 mm total width. IP20 on the device body, IP40 inside a modular enclosure. Rated insulation voltage 500 V AC, operational voltage 400…415 V AC at 50/60 Hz, impulse withstand 6 kV per EN/IEC 61009-1. Pollution degree 3 — suitable for industrial panels where conductive contamination is controlled but not excluded. The 30 mA sensitivity catches leakage currents that could be lethal through a grounded person — standard for socket-outlet and final-circuit protection in many jurisdictions. Type A detection covers sinusoidal AC faults plus pulsating DC, which is what most single-phase electronics and switched-mode power supplies generate. Instantaneous trip means no intentional time delay; it clears the fault within the standard response time of the RCD mechanism. Ambient operating range -25…60 °C, storage -40…85 °C.","metaTitle":"Schneider Electric A9V07263 Vigi iC60 RCD, 2P 63A 30mA Type","metaDescription":"Schneider Electric A9V07263 Acti9 Vigi iC60 add-on RCD, 2P, 63A, 30mA, Type A, instantaneous. Obsolete — sourced to order against RFQ. EN/IEC 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"72 mm","Height":"91 mm","Voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4fc9f7e3de9cd39cae3b6a4a5c9a3979.pdf","sourceUrl":"https://www.se.com/za/en/product/A9V07263/addon-residual-current-device-acti9-vigi-ic60-2p-63a-a-type-instantaneous-30ma-400-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V07263/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V07263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V07263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}