{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V11340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V11340","canonicalUrl":"https://aoctrl.com/schneider/A9V11340","factsUrl":"https://aoctrl.com/api/mcp/products/A9V11340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 40 A, 30 mA, Type AC, 400-415 V AC, 50/60 Hz, clip-on DIN rail mount, IP20, obsolete.","salesMarkdown":"Rated 40 A with 30 mA sensitivity, it protects against sinusoidal AC fault currents in 3P (three-pole) circuits at 400-415 V AC, 50/60 Hz. The voltage-independent tripping technology means it operates without an external power supply, relying on the fault current itself to trigger the mechanism. The 30 mA earth-leakage sensitivity is the standard threshold for personal protection against fatal electric shock — it trips before a fault current reaches a level that could cause ventricular fibrillation. The voltage-independent tripping is a reliability advantage: the device does not depend on the supply voltage to operate, so it provides protection even if the neutral is lost upstream. The 8/20 µs impulse withstand of 250 A confirms the device can survive transient surge currents without nuisance tripping or damage. Clip-on mounting onto a DIN rail — standard 35 mm symmetrical rail. The device occupies 7 x 9 mm pitches, so the width is 117 mm for the 3P unit. Depth is 73.5 mm, height 91 mm. It is designed as an outgoer device, meaning it sits on the load side of the breaker. The electrical connection to the MCB is by screws; bottom terminals are tunnel type accepting 1-35 mm² rigid or 1-25 mm² flexible cable. The comb busbar and distribution block compatibility is confirmed for the bottom side. The local trip indicator provides a visual confirmation of the tripped state, aiding fault-finding on the panel.","metaTitle":"Schneider Electric A9V11340 Vigi iC60 3P 40A 30mA RCD, obsol","metaDescription":"Schneider Electric A9V11340 Acti9 Vigi iC60 add-on residual current device, 3P, 40A, 30mA, Type AC. Obsolete; sourced to order against RFQ. 400-415 VAC, 50/60 Hz.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"117 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"3.5 N.m bottom","[In] rated current":"40 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b8f53ea7e8cfeb9ee794fc0f26340dbf.pdf","sourceUrl":"https://www.se.com/id/en/product/A9V11340/addon-residual-current-device-acti9-vigi-ic60-3p-40a-30ma-ac-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V11340/alternatives.json"},"ai":{"faq":[{"question":"What is the A9V11340 used for?","answer":"It is an add-on residual current device (RCD) for the Acti9 iC60 miniature circuit breaker, providing 30 mA earth-leakage protection in three-phase (3P) AC circuits at 400-415 V, 50/60 Hz. It is voltage-independent and Type AC, meaning it detects sinusoidal AC fault currents only."},{"question":"What is the closest alternative to the A9V11340?","answer":"No official successor order code is listed by the manufacturer. A parametric replacement would need to match: 40 A rated current, 30 mA sensitivity, Type AC, 3P, voltage-independent tripping, and physical compatibility with the iC60 breaker and DIN-rail mounting. Consult a sourcing specialist to evaluate current active Acti9 Vigi iC60 variants for fit."},{"question":"Where can I buy the A9V11340?","answer":"We source this obsolete part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm offer."},{"question":"What compliance documentation does Schneider provide for the A9V11340?","answer":"The device is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. Standard compliance documentation (declaration of conformity, test reports) is available from Schneider Electric's documentation portal for the Acti9 Vigi iC60 range. Specific RoHS, REACH, and UL status should be verified from the manufacturer's current documentation for this obsolete order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V11340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V11340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}