{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V14225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V14225","canonicalUrl":"https://aoctrl.com/schneider/A9V14225","factsUrl":"https://aoctrl.com/api/mcp/products/A9V14225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 25 A, 300 mA, Type AC, clip-on DIN rail mount, 73.5 mm depth.","salesMarkdown":"The Schneider Electric A9V14225 is a Vigi iC60 add-on residual current device (RCD) from the Acti9 range, designed to clip onto the side of an iC60 MCB to provide earth leakage protection in a 2-pole configuration. Rated at 25 A with a 300 mA sensitivity, it is a Type AC (sinusoidal AC only) voltage-independent instantaneous trip unit, meaning it operates without needing an external power supply — the fault current itself triggers the mechanism. It mounts on a DIN rail via clip-on and occupies 3 x 9 mm pitches (63 mm wide), fitting standard modular enclosures with an IP40 face and IP20 terminal protection. The 230...415 V AC operational voltage range (50/60 Hz) covers single-phase and two-phase line-to-line applications across standard European and Asian distribution networks. The 8/20 µs impulse withstand of 250 A (per IEC 61009-1) confirms the RCD can survive surge currents from nearby lightning or switching events without damage. The A9V14225 is listed as obsolete by Schneider Electric. No direct official successor order code is provided in the available records, so replacement typically requires reviewing the current Acti9 Vigi iC60 catalog for a functionally equivalent 2P 25A 300mA Type AC add-on block. ## Wiring and integration notes The add-on block connects to the iC60 MCB via screws (tunnel-type terminals), accepting 1 to 25 mm² rigid or 1 to 16 mm² flexible conductors on the bottom side. A trip indicator provides local visual signalling of RCD operation, and the unit is compatible with bottom-entry comb busbars and distribution blocks. Depth of 73.5 mm and height of 91 mm fit standard Acti9 enclosures; verify clearance for the add-on block when mounted adjacent to other devices on the same DIN rail.","metaTitle":"A9V14225 Vigi iC60 2P 25A 300mA AC Type RCD Add-On Block","metaDescription":"Schneider Electric A9V14225 Vigi iC60 add-on RCD block, 2P, 25A, 300mA, Type AC. Obsolete status; sourced to order against RFQ. Depth 73.5mm, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"63 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"3","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9996b135bbf0fb5357e2a823dcc37cc9.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9V14225/vigi-ic60-earth-leakage-addon-block-2p-25a-300ma-ac-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V14225/alternatives.json"},"ai":{"faq":[{"question":"What replaces the A9V14225?","answer":"No direct official successor order code is provided in the available records. For a current-production equivalent, review the latest Acti9 Vigi iC60 catalog for a 2P 25A 300mA Type AC add-on RCD block."},{"question":"What standards does the A9V14225 comply with?","answer":"It complies with EN/IEC 61009-1 and EN/IEC 61009-2-1 for RCDs, and IEC 60947-2 for the impulse withstand and pollution degree ratings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V14225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V14225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}