{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V16363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V16363","canonicalUrl":"https://aoctrl.com/schneider/A9V16363","factsUrl":"https://aoctrl.com/api/mcp/products/A9V16363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 63 A, 500 mA Type AC, instantaneous, 230…415 V AC, clip-on DIN rail.","salesMarkdown":"The A9V16363 is a 3-pole add-on residual current device (RCD) from the Acti9 Vigi iC60 family, rated 63 A with 500 mA sensitivity, Type AC, instantaneous trip. The 63 A continuous rating matches the load current of a 3-phase outgoer — sized for a sub-distribution board feeding lighting or general-purpose socket circuits. The 500 mA earth-leakage threshold is not personnel protection (30 mA is the touch-safety limit); this is equipment-protection level, used where a higher leakage floor is tolerable to avoid nuisance tripping on long cable runs or equipment with natural leakage. Voltage-independent tripping means the RCD operates without needing a control supply — it uses the fault energy itself, so it works even if the neutral is lost upstream. ## Deployment context Occupies 7 x 9 mm pitches, so 63 mm of DIN width. Terminal tunnel accepts 1…35 mm² rigid or 1…25 mm² flexible; tighten to 3.5 N·m bottom. Wire strip length 14 mm. Comb busbar compatible from the bottom.","metaTitle":"A9V16363 Acti9 Vigi iC60 3P 63A 500mA Type AC RCD, Add-On","metaDescription":"A9V16363 Acti9 Vigi iC60 add-on RCD, 3P, 63A, 500 mA Type AC, instantaneous, 230-415 VAC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"117 mm","title":"A9V16363","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Add-on residual current device, Acti9 Vigi iC60, 3P, 63A, AC type, instantaneous, 500mA, 230...415VAC","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"500 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/45180f40195e287752a6adbc5cd1b38a.pdf","sourceUrl":"https://www.se.com/hk/en/product/A9V16363/addon-residual-current-device-acti9-vigi-ic60-3p-63a-ac-type-instantaneous-500ma-230-415vac/"},"ai":{"faq":[{"question":"What is the A9V16363 used for?","answer":"It is a 3-pole add-on residual current device for 63 A circuits, providing 500 mA Type AC earth-leakage protection on 230…415 V AC networks. It clips onto a DIN-rail-mounted MCB and protects equipment, not personnel."},{"question":"Where can I buy the A9V16363?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V16363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V16363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}