{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V19263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V19263","canonicalUrl":"https://aoctrl.com/schneider/A9V19263","factsUrl":"https://aoctrl.com/api/mcp/products/A9V19263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 63 A, AC type, selective, 1000 mA, 230…415 VAC, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9V19263 is an Acti9 Vigi iC60 add-on residual current device (RCD) — a voltage-independent, 2-pole unit rated 63 A with a 1000 mA AC-type earth-leakage sensitivity, selective time delay, and 230…415 VAC operational range. The A9V19263 is listed as Obsolete by Schneider Electric. If you are maintaining a panel design that specifies this part, verify whether the wider Acti9 Vigi iC60 range has a current-production variant with the same 2P, 63 A, 1000 mA, AC-type, selective parameters — the physical footprint and connection scheme are consistent across the family, but the order code change and any certification recertification need checking against your assembly documentation. ## Wiring and panel integration Mounts by clip-on onto a DIN rail, occupying 4 x 9 mm pitches (72 mm width). The bottom side is also compatible with comb busbars and distribution blocks, so it can be fed from a common busbar run alongside the MCB. IP20 on the device body, IP40 inside a modular enclosure. Pollution degree 3 per IEC 60947-2 — suitable for standard industrial panel environments, not sealed outdoor locations. Rated insulation voltage 500 V AC; impulse withstand 6 kV per IEC 60947-2. Impulse withstand on the residual current path: 8/20 µs, 3000 A per IEC 61009-1. Ambient operation -5…60 °C, storage -40…85 °C.","metaTitle":"Schneider Electric A9V19263 Vigi iC60 RCD, 2P 63A AC type se","metaDescription":"Obsolete Schneider A9V19263 Acti9 Vigi iC60 add-on RCD, 2P, 63A, AC type, selective, 1000mA. Sourced to order. Confirm fit on your BOM line.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"72 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"1000 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b6c0340c12074dd5f731a757fd62e514.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9V19263/addon-residual-current-device-acti9-vigi-ic60-2p-63a-ac-type-selective-1000ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V19263/alternatives.json"},"ai":{"faq":[{"question":"What is the difference between AC type and A type RCD?","answer":"AC type (this unit) detects sinusoidal AC earth-leakage current only. It does not detect pulsed DC or smooth DC fault currents. If your load includes rectifiers, VFDs, or switching power supplies that can generate DC leakage, an A type or B type RCD would be required. The A9V19263 is AC type only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V19263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V19263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}