{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V19363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V19363","canonicalUrl":"https://aoctrl.com/schneider/A9V19363","factsUrl":"https://aoctrl.com/api/mcp/products/A9V19363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 63 A, 1000 mA sensitivity, AC type, selective, clip-on DIN rail mount.","salesMarkdown":"It's a 3-pole unit rated 63 A with 1000 mA sensitivity, AC type (sinusoidal AC fault detection), and selective (time-delayed) tripping to coordinate with downstream RCDs. Mounts on DIN rail via the clip-on mechanism, occupying 7 x 9 mm pitches (117 mm width). The 63 A rated current (In) matches the upstream MCB's frame — this block is sized for a 63 A outgoing circuit, not for general-purpose 40 A or 25 A feeders. The 1000 mA sensitivity is a deliberate choice: it's not for personnel protection (which typically requires 30 mA), but for equipment protection or fire prevention on large circuits where nuisance tripping from normal leakage must be avoided. The selective (time-delayed) characteristic means it holds through transient earth faults and lets downstream 30 mA RCDs trip first — essential for discrimination in a multi-level distribution board. Rated operational voltage covers 230...415 V AC 50/60 Hz, which spans single-phase and three-phase networks up to 415 V line-to-line. Insulation voltage is 500 V AC, and impulse withstand is 6 kV — adequate for standard industrial and commercial panels. The AC-type detection handles sinusoidal faults only; if the installation has electronic loads generating pulsed or DC fault currents, a Type A or Type B RCD would be needed instead. Clip-on mounting to DIN rail, 7 module pitches wide (117 mm). Strip length 14 mm for bottom connections. Bottom busbar compatible, which simplifies distribution in multi-circuit panels. Operating temperature range -5...60 °C, storage -40...85 °C. The trip indicator gives local visual confirmation of RCD operation — useful during fault-finding without needing to meter the circuit.","metaTitle":"Schneider Electric A9V19363 Vigi iC60 RCD, 63A 1000mA AC Typ","metaDescription":"Schneider Electric A9V19363 Acti9 Vigi iC60 add-on RCD, 3P, 63A, 1000mA, AC type, selective. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"117 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"1000 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/52990344c851b80e8e2902c0980010f4.pdf","sourceUrl":"https://www.se.com/ae/en/product/A9V19363/vigi-ic60-earth-leakage-addon-block-3p-63a-1000ma-ac-type-selective/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V19363/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of A9V19363?","answer":"63 A rated current, 1000 mA earth-leakage sensitivity, AC type (sinusoidal fault detection), selective (time-delayed) tripping, 3-pole, rated operational voltage 230...415 V AC 50/60 Hz, insulation voltage 500 V AC, impulse withstand 6 kV."},{"question":"Where can I buy A9V19363?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position."},{"question":"What standards does A9V19363 comply with?","answer":"Compliant with EN/IEC 61009-1 and EN/IEC 61009-2-1 for residual current operated circuit-breakers, plus IEC 60947-2 for insulation and impulse withstand ratings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V19363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V19363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}