{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V19463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V19463","canonicalUrl":"https://aoctrl.com/schneider/A9V19463","factsUrl":"https://aoctrl.com/api/mcp/products/A9V19463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 4P, 63 A, AC type, selective, 1000 mA, 230...415 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9V19463 is an Acti9 Vigi iC60 add-on residual current device — 4P, rated 63 A, AC type, selective time delay, 1000 mA sensitivity. The 1000 mA threshold and selective delay mean it coordinates downstream: it lets transient earth faults ride through and only trips on sustained leakage above that level, keeping nuisance trips off the main incomer. Voltage-independent tripping means it clears a ground fault even if the phase voltage collapses — no auxiliary supply needed. Clip-on mount to standard DIN rail. Width 135 mm (7 x 9 mm pitches), depth 73.5 mm, height 91 mm. Bottom tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible; tighten to 3.5 N·m. Strip 14 mm. IP20 on the device body; IP40 inside a modular enclosure. Comb-busbar compatible on the bottom side for daisy-chaining neutrals or phases across a row of Vigi units.","metaTitle":"Schneider Electric A9V19463 Acti9 Vigi iC60, 4P, 63A, AC typ","metaDescription":"Schneider Electric A9V19463 Acti9 Vigi iC60 add-on RCD, 4P, 63A, AC type, selective 1000mA, 230-415VAC. Active lifecycle. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"135 mm","title":"A9V19463","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Add-on residual current device, Acti9 Vigi iC60, 4P, 63A, AC type, selective, 1000mA, 230...415VAC","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"1000 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43b8a1d7e65a28b2beb27b27146cb90d.pdf","sourceUrl":"https://www.se.com/uk/en/product/A9V19463/addon-residual-current-device-acti9-vigi-ic60-4p-63a-ac-type-selective-1000ma-230-415vac/"},"ai":{"faq":[{"question":"What is A9V19463's earth leakage protection type?","answer":"AC type, selective time delay, 1000 mA sensitivity. Voltage-independent tripping — operates without an external power supply."},{"question":"What is the rated current and voltage for A9V19463?","answer":"Rated current 63 A, rated operational voltage 230...415 V AC (50/60 Hz). Insulation voltage 500 V AC."},{"question":"Where can I buy A9V19463?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V19463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V19463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}