{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V21263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V21263","canonicalUrl":"https://aoctrl.com/schneider/A9V21263","factsUrl":"https://aoctrl.com/api/mcp/products/A9V21263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V21263, 2P, 63 A, 30 mA Type A instantaneous, 230-240 V AC, DIN-rail clip-on.","salesMarkdown":"The A9V21263 is a voltage-independent, add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to snap onto the side of a compatible iC60 MCB. It adds earth-leakage protection to that circuit without needing a separate power supply for the trip coil — the trip energy comes from the fault itself, so it still clears a line-to-ground fault even if the neutral is lost. Rated 63 A continuous, with a 30 mA sensitivity, Type A (pulsating DC and sinusoidal AC leakage), and instantaneous trip. That means it catches both pure AC faults and the pulsed DC waveform from downstream electronics — rectifiers, VFDs, switched-mode supplies — common on modern panels. The 30 mA threshold is the standard for personal protection against electric shock. The screw terminals torque to 3.5 N·m. Strip length is 14 mm for the bottom connection. The 8/20 µs impulse withstand of 250 A (per IEC 61009-1) means the internal sense coil can handle a lightning-induced surge without saturating or nuisance-tripping. This is a practical spec for outdoor-fed residential or light commercial boards. Clip-on mounting to DIN rail. The module is 72 mm wide (4 pitches), 91 mm tall, 73.5 mm deep. It sits on the outgoing side of the MCB, mechanically linked via screws — so it shares the same busbar and occupies the same DIN-rail footprint as the breaker. IP20 on the front (finger-safe), IP40 inside a modular enclosure. Fine for a clean panel; if the board is in a washdown area, you'll need an outer cabinet. The storage range is wider — that's the shipping and shelf-life limit, not the running limit.","metaTitle":"A9V21263 Acti9 Vigi iC60 RCD, 2P, 63A, 30mA Type A","metaDescription":"A9V21263 Acti9 Vigi iC60 add-on RCD, 2P 63A, 30mA Type A instantaneous, 230-240V AC. Active production, DIN-rail mount. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"72 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/27a9289f37843d35452686a7fd0f932b.pdf","sourceUrl":"https://www.se.com/za/en/product/A9V21263/addon-residual-current-device-acti9-vigi-ic60-2p-63a-a-type-instantaneous-30ma-230-240vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V21263/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9V21263 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote — no stock or price figures are published here."},{"question":"What is the depth of A9V21263?","answer":"The A9V21263 has a depth of 73.5 mm."},{"question":"What is the range of A9V21263?","answer":"The A9V21263 belongs to the Acti9 range from Schneider Electric."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V21263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V21263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}