{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V24425","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V24425","canonicalUrl":"https://aoctrl.com/schneider/A9V24425","factsUrl":"https://aoctrl.com/api/mcp/products/A9V24425","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V24425, 4 poles, 25 A rated current, 300 mA Type A earth leakage, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9V24425 is an Acti9 Vigi iC60 add-on residual current device (RCD) — a 4-pole, 25 A, 300 mA Type A earth leakage block that clips onto the outgoing side of a compatible iC60 MCB. Voltage-independent tripping means it operates without needing a separate power supply to the electronics; the fault current itself drives the mechanism. Rated operational voltage is 400 V AC at 50/60 Hz, with an insulation voltage of 500 V AC and impulse withstand of 6 kV per IEC 60947-2. Pollution degree 3 rated, so it handles the conductive deposits typical in industrial control panels. This order code is marked obsolete by the manufacturer. Mounts via clip-on onto a DIN rail, occupying 6 x 9 mm pitches (54 mm width). The bottom tunnel terminals accept 1…25 mm² rigid cable or 1…16 mm² flexible (with or without ferrule), tightened to 2 N·m. The add-on block screws directly to the adjacent iC60 MCB — no extra wiring between the two devices. IP20 rated (finger-safe), IP40 inside a modular enclosure. Trip indicator provides local visual signalling of a residual current event. Compliant with EN 61009-1 and IEC 61009-1 for RCBOs (combined MCB/RCD standards). The 8/20 µs impulse withstand rating of 250 A per IEC 61009-1 confirms it survives surge events without nuisance tripping. Ambient operating range is -25…60 °C; storage range -40…85 °C.","metaTitle":"Schneider Electric A9V24425 Vigi iC60 RCD, 4P 25A 300mA Type","metaDescription":"Schneider Electric A9V24425 Acti9 Vigi iC60 add-on RCD. 4 poles, 25A rated current, 300mA Type A earth leakage. Obsolete — sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"54 mm","Height":"91 mm","Standards":"EN 61009-1 IEC 61009-1","9 Mm Pitches":"6","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz conforming to EN 61009-1 400/415 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7e66304008b09d05a20c7e2cac5a91b2.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9V24425/vigi-ic60-earth-leakage-addon-block-4p-25a-300ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V24425/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9V24425?","answer":"The A9V24425 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the A9V24425 used for?","answer":"The A9V24425 is an add-on residual current device (RCD) for the Acti9 iC60 MCB range. It provides Type A earth leakage protection (300 mA sensitivity) on a 4-pole, 25 A circuit at 400 V AC, typically in industrial or commercial distribution boards."},{"question":"What are the key specifications of A9V24425?","answer":"Key specs: 4 poles, 25 A rated current, 300 mA Type A earth leakage, 400 V AC operational voltage, clip-on DIN rail mount, 54 mm width (6 x 9 mm pitches), IP20/IP40 protection, voltage-independent tripping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V24425","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V24425 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}