{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V26263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V26263","canonicalUrl":"https://aoctrl.com/schneider/A9V26263","factsUrl":"https://aoctrl.com/api/mcp/products/A9V26263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V26263, 2-pole, 63 A rated current, Type A, 500 mA sensitivity, instantaneous, 230…415 VAC, DIN-rail clip-on.","salesMarkdown":"The A9V26263 is an add-on residual current device (RCD) from the Schneider Acti9 Vigi iC60 family. It clips onto the downstream side of a compatible iC60 MCB to add earth-leakage protection to that circuit. Rated 63 A continuous, with a 500 mA trip sensitivity and Type A waveform detection, it catches sinusoidal AC faults plus pulsating DC faults up to 6 mA of smooth DC — the kind you get from single-phase rectifiers in VFDs, switching supplies, or dimmers. The trip is instantaneous — no intentional time delay — so it clears a ground fault as fast as the internal mechanics can move. That makes it a good fit for outgoing circuits where you want fast isolation of a live-to-ground fault, not selectivity with downstream RCDs. Mechanically it's a voltage-independent design: the trip coil draws its energy from the fault current itself, not from an external power supply. That means a lost neutral or a dropped control voltage won't disable the earth-leakage protection — it still trips on a live-to-ground fault as long as the phase conductor is energized. Snap-on DIN-rail mounting, standard 9 mm pitch — this unit occupies 4 pitches (72 mm wide). The 73.5 mm depth leaves clearance for wiring in a standard enclosure; the 91 mm height fits under most distribution-board covers. Bottom terminals are tunnel-type, accepting one conductor per side: 1…35 mm² rigid, 1…25 mm² flexible (with or without ferrule). Strip length 14 mm, torque to 3.5 N·m. A comb busbar can feed the line side, which saves daisy-chaining wire when ganging multiple RCDs or MCBs on the same phase. IP20 on the body, IP40 inside a modular enclosure — standard for a panelboard device. Not a washdown part; keep it inside a dry cabinet. ## Electrical ratings and standards Insulation voltage 500 V AC, impulse withstand 6 kV per IEC 60947-2. Compliant with EN/IEC 61009-1 and EN/IEC 61009-2-1, the standards for RCBOs (combined MCB/RCD) and for RCDs intended to be used with MCBs. The impulse withstand rating on the residual-current side is 250 A, 8/20 µs waveform per IEC 61009-1 — it survives surge currents from nearby lightning or switching without nuisance tripping. Ambient operating range -25…60 °C; storage -40…85 °C. If you're freezing a BOM or filling a line-down replacement, the A9V26263 is a straightforward fit. The 500 mA sensitivity and Type A characteristic are common choices for general-purpose final circuits; just confirm the upstream MCB's thermal-magnetic curve coordinates with the instantaneous RCD trip so you don't get nuisance openings on motor-start inrush or capacitor charging.","metaTitle":"Schneider Electric A9V26263 Acti9 Vigi iC60, 2P, 63A, 500mA,","metaDescription":"Active production A9V26263 Acti9 Vigi iC60 add-on RCD. 2P, 63A, Type A, 500 mA sensitivity, instantaneous. DIN-rail mount. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"72 mm","Height":"91 mm","Voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8b8002b2d7308cd2b179da152288f57e.pdf","sourceUrl":"https://www.se.com/uk/en/product/A9V26263/addon-residual-current-device-acti9-vigi-ic60-2p-63a-a-type-instantaneous-500ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V26263/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V26263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V26263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}