{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V26325","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V26325","canonicalUrl":"https://aoctrl.com/schneider/A9V26325","factsUrl":"https://aoctrl.com/api/mcp/products/A9V26325","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 25 A, 500 mA, Type A, voltage-independent, instantaneous, DIN-rail clip-on.","salesMarkdown":"The Schneider Electric A9V26325 is a Vigi iC60 add-on residual current device (RCD) from the Acti9 range — a 3-pole, 25 A, 500 mA, Type A earth-leakage block designed to clip onto the side of an iC60 MCB. It provides voltage-independent, instantaneous residual current protection for outgoing circuits in distribution boards. Rated 25 A at 230...415 V AC 50/60 Hz, so it protects downstream circuits up to that current on a three-phase or single-phase network. The 500 mA sensitivity is a high-threshold setting — suited for equipment protection or circuits where nuisance tripping from leakage in long cable runs or industrial loads must be avoided, not for personnel protection (which typically requires 30 mA or lower). Type A protection detects sinusoidal AC and pulsating DC residual currents, covering most modern electronic loads like VFDs, UPS systems, and switching power supplies. Rated insulation voltage 500 V AC and impulse withstand 6 kV per IEC 60947-2, with pollution degree 3 — suitable for industrial distribution panels where transient overvoltages and conductive contamination are expected. IP20 (IP40 in modular enclosure) — intended for enclosed distribution boards, not washdown environments.","metaTitle":"A9V26325 Vigi iC60 Earth Leakage Add-on Block, 3P 25A 500mA","metaDescription":"Schneider Electric A9V26325 Vigi iC60 add-on RCD, 3P, 25A, 500mA, Type A. Obsolete — sourced to order against RFQ. EN/IEC 61009-1. DIN-rail clip-on.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"54 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"6","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"500 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/030a23fb70cc03b5cfdb524792a82f7c.pdf","sourceUrl":"https://www.se.com/ae/en/product/A9V26325/vigi-ic60-earth-leakage-addon-block-3p-25a-500ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V26325/alternatives.json"},"ai":{"faq":[{"question":"What is A9V26325 used for?","answer":"The A9V26325 is an add-on residual current device (RCD) that clips onto a Vigi iC60 MCB to add earth-leakage protection to the circuit. It is used in Acti9 distribution boards for outgoing circuits requiring Type A, 500 mA, instantaneous protection."},{"question":"What are the key specifications of A9V26325?","answer":"3-pole, 25 A rated current, 500 mA earth-leakage sensitivity, Type A, voltage-independent, instantaneous trip, 230...415 V AC 50/60 Hz, DIN-rail clip-on, 54 mm wide, IP20, compliant with EN/IEC 61009-1 and EN/IEC 61009-2-1."},{"question":"Where can I buy A9V26325?","answer":"The A9V26325 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V26325","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V26325 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}