{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V29363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V29363","canonicalUrl":"https://aoctrl.com/schneider/A9V29363","factsUrl":"https://aoctrl.com/api/mcp/products/A9V29363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V29363, 3P, 63 A, Type A, selective, 1000 mA, 230…415 V AC.","salesMarkdown":"The Schneider Electric A9V29363 is an Acti9 Vigi iC60 add-on residual current device, 3-pole, rated 63 A with a 1000 mA Type A earth-leakage sensitivity and selective time delay. The voltage-independent tripping means it clears a ground fault even if the line voltage collapses — no auxiliary supply needed. The 63 A [In] is the continuous current the Vigi iC60 can carry without derating in a 30 °C ambient — match it to the upstream MCB rating. The 1000 mA sensitivity is selective (time-delayed), so it coordinates downstream of a 30 mA or 300 mA RCD; the selective delay lets the downstream device trip first on a hard fault, keeping only the branch off instead of the whole submain. Type A protection covers sinusoidal AC and pulsating DC residual currents up to 6 mA smooth DC — the standard for single-phase electronics loads like VFDs, UPSs, and LED drivers. Clip-on DIN-rail mounting, 7 x 9 mm pitches (117 mm wide). The bottom tunnel terminals accept 1…35 mm² rigid or 1…25 mm² flexible (with or without ferrule), stripped to 14 mm, torqued to 3.5 N.m. Electrical connection to the adjacent MCB is by screws — no busbar jumper needed between the two units. IP20 on the body, IP40 inside a modular enclosure.","metaTitle":"Schneider Electric A9V29363 Acti9 Vigi iC60 RCD, 3P, 63A, 10","metaDescription":"Schneider Electric A9V29363 Acti9 Vigi iC60 add-on RCD, 3P, 63A, Type A, selective 1000mA, 230-415VAC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"117 mm","title":"A9V29363","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Add-on residual current device, Acti9 Vigi iC60, 3P, 63A, A type, selective, 1000mA, 230...415VAC","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"1000 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4fdad94cb10321b8804b4be40af6e639.pdf","sourceUrl":"https://www.se.com/sa/en/product/A9V29363/addon-residual-current-device-acti9-vigi-ic60-3p-63a-a-type-selective-1000ma-230-415vac/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9V29363?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does this brand provide for A9V29363?","answer":"The A9V29363 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. It carries IP20 (IEC 60529) and IP40 in modular enclosure, with impulse withstand of 8/20 µs, 3000 A per IEC 61009-1. Rated insulation voltage 500 V AC, rated impulse withstand 6 kV per IEC 60947-2."},{"question":"What is A9V29363's listed depth?","answer":"The A9V29363 has a depth of 73.5 mm, width 117 mm, height 91 mm. It occupies 7 x 9 mm pitches on the DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V29363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V29363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}