{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V31225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V31225","canonicalUrl":"https://aoctrl.com/schneider/A9V31225","factsUrl":"https://aoctrl.com/api/mcp/products/A9V31225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 25 A rated current, 30 mA sensitivity, Type A-SI (Super Immunised), DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9V31225 is an Acti9 Vigi iC60 add-on residual current device — a 2-pole, 25 A, 30 mA unit with Type A-SI (Super Immunised) earth leakage protection. It clips onto the DIN rail alongside the companion MCB, making it a straightforward fit in a standard distribution board. Rated operational voltage is 230...240 V AC at 50/60 Hz, per EN/IEC 61009-1. The 25 A rating matches the load current of the protected circuit — sized for a branch feeding a group of outlets or a small lighting panel. The 30 mA sensitivity is the standard touch-protection threshold (IEC 61009-1), meaning it will trip on leakage currents that could be hazardous to a person. Type A-SI (Super Immunised) means it handles pulsed DC fault currents (typical from variable-speed drives or power supplies) without nuisance tripping, and it resists false trips from transient surges. That SI suffix matters if you have electronic loads on the circuit; a standard Type A might drop out when a drive starts up. The residual current tripping is voltage-independent — it will still detect a ground fault and trip even if the phase-to-neutral voltage collapses. That is a reliability feature for circuits where a lost neutral could otherwise leave a fault undetected. Mechanically, it occupies 3 x 9 mm pitches (63 mm wide) on a DIN rail, clips on without tools, and accepts tunnel-type terminals for 1 to 25 mm² rigid cable at the bottom. The IP20 body is fine for enclosed distribution boards; the modular enclosure carries IP40 once installed.","metaTitle":"Schneider A9V31225 Acti9 Vigi iC60 RCD, 2P 25A 30mA SI","metaDescription":"Schneider A9V31225 Acti9 Vigi iC60 add-on RCD, 2P, 25A, 30mA, Type A-SI. Obsolete — sourced to order against RFQ. EN/IEC 61009-1. DIN rail clip-on.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"63 mm","Height":"91 mm","Standards":"EN 61009-1 IEC 61009-1","9 Mm Pitches":"3","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...240 V AC 50/60 Hz conforming to EN 61009-1 230...240 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cafa27bf33db6e6a4502a3a2869026a8.pdf","sourceUrl":"https://www.se.com/ie/en/product/A9V31225/vigi-ic60-earth-leakage-addon-block-2p-25a-30ma-si-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V31225/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9V31225?","answer":"We source the A9V31225 to order against an RFQ through independent distribution and surplus channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a current status."},{"question":"What does Type A-SI earth leakage protection mean?","answer":"Type A-SI (Super Immunised) detects both sinusoidal AC and pulsed DC fault currents, and is designed to resist nuisance tripping from transient surges or inrush currents common with electronic loads like drives and switching power supplies."},{"question":"What standards does A9V31225 comply with?","answer":"The A9V31225 complies with EN 61009-1 and IEC 61009-1 for residual current circuit breakers, and IEC 60947-2 for the insulation and impulse withstand voltage ratings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V31225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V31225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}