{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V31325","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V31325","canonicalUrl":"https://aoctrl.com/schneider/A9V31325","factsUrl":"https://aoctrl.com/api/mcp/products/A9V31325","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 25 A rated current, 30 mA sensitivity, Type A-SI (Super Immunised), obsolete.","salesMarkdown":"It's a 3-pole unit rated 25 A continuous with a 30 mA trip sensitivity, Type A-SI (Super Immunised), meaning it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads. Rated operational voltage is 400 V AC at 50/60 Hz, with an insulation voltage of 500 V AC and impulse withstand of 6 kV per IEC 60947-2. Clip-on mounting to DIN rail, 6 module pitches wide (54 mm). The add-on block screws directly to the side of an iC60 MCB — the electrical connection is by screws, bottom terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable. IP20 finger-safe, IP40 inside a modular enclosure. The 30 mA sensitivity is the standard for personnel protection (shock hazard) per IEC 61009-1. Type A-SI (Super Immunised) means it's designed to stay put on circuits with variable-speed drives, UPS systems, or LED lighting — loads that generate smooth DC fault currents or high-frequency leakage that would trip a standard Type A or AC RCD. The voltage-independent tripping technology means the RCD operates even if the line voltage drops or is lost, which is critical for safety in fault conditions. Instantaneous trip time (no intentional delay) means it clears fast on a ground fault, but selectivity with downstream RCDs may require coordination — not a problem for a single outgoer circuit.","metaTitle":"Schneider Electric A9V31325 Acti9 Vigi iC60, 25A 30mA SI, Ob","metaDescription":"Schneider Electric A9V31325 Acti9 Vigi iC60 add-on RCD, 3P, 25A, 30mA, Type A-SI. Obsolete per manufacturer. Sourced to order against RFQ. IEC 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"54 mm","Height":"91 mm","Standards":"IEC 61009-1 EN 61009-1","9 Mm Pitches":"6","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz conforming to EN 61009-1 400/415 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe6feee72e3b10a1c0f0729be28b1b9e.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9V31325/vigi-ic60-earth-leakage-addon-block-3p-25a-30ma-si-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V31325/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9V31325 and how is it quoted?","answer":"We source the A9V31325 to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest alternative to A9V31325?","answer":"There is no official Schneider successor order code listed for this part. The closest functional match would be another Acti9 Vigi iC60 add-on block with the same 3P, 25 A, 30 mA, Type A-SI rating — but the exact order code may differ. Check the current Acti9 catalog for the active equivalent."},{"question":"What compliance documentation does A9V31325 carry?","answer":"The A9V31325 is certified to IEC 61009-1 and EN 61009-1. It carries IP20/IP40 protection ratings per IEC 60529, and pollution degree 3 per IEC 60947-2. Specific RoHS/REACH/UL documentation should be verified against the manufacturer's current declarations for this obsolete part."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V31325","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V31325 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}