{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V39463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V39463","canonicalUrl":"https://aoctrl.com/schneider/A9V39463","factsUrl":"https://aoctrl.com/api/mcp/products/A9V39463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on RCD, 4P, 63 A, Type A-SI, 1000 mA, selective, 230…415 VAC, clip-on DIN rail, IP20/IP40.","salesMarkdown":"The Schneider Electric A9V39463 is an Acti9 Vigi iC60 add-on residual current device, 4 poles, rated 63 A, with a 1000 mA earth-leakage sensitivity. The 1000 mA sensitivity and Type A-SI (Super Immunised) characteristic mean this RCD is designed for circuits where nuisance tripping from high-frequency harmonics or pulsed DC must be avoided — typical for variable-speed drives, UPS outputs, or industrial equipment with electronic loads. The 'selective' time delay (S-type) coordinates with downstream RCDs: it holds during a fault long enough for the downstream device to clear first, so only the faulted branch drops out. Rated operational voltage is 230…415 V AC, 50/60 Hz, covering single-phase and three-phase networks up to 415 V line-to-line. The 4-pole construction handles three-phase plus neutral, so it fits three-phase outgoing feeders in distribution boards. The voltage-independent tripping mechanism means the RCD detects leakage current and trips even if the phase voltage is lost — a safety advantage over electronically dependent types that may fail to trip on a lost neutral. Clip-on mounting to DIN rail, 7 x 9 mm pitches wide (135 mm). Tightening torque 3.5 N.m. The add-on design screws directly to the outgoing side of an iC60 MCB — no extra wiring between the two.","metaTitle":"Schneider Electric A9V39463 Acti9 Vigi iC60, 4P, 63A, A-SI,","metaDescription":"Schneider Electric A9V39463 Acti9 Vigi iC60 add-on RCD, 4P, 63 A, Type A-SI, 1000 mA, selective, 230…415 VAC. Active lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"135 mm","title":"A9V39463","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","description":"Add-on residual current device, Acti9 Vigi iC60, 4P, 63A, A-SI type, selective, 1000mA, 230...415VAC","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"1000 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/641217312c873dcf32d8c1b2f9dd1ed1.pdf","sourceUrl":"https://www.se.com/sa/en/product/A9V39463/addon-residual-current-device-acti9-vigi-ic60-4p-63a-asi-type-selective-1000ma-230-415vac/"},"ai":{"faq":[{"question":"What is A9V39463 used for?","answer":"The A9V39463 is an add-on residual current device (RCD) for the Acti9 iC60 MCB range, providing earth-leakage protection on 4-pole circuits up to 63 A, 415 V AC, with a 1000 mA sensitivity and selective time delay for coordination in distribution boards."},{"question":"Where can I buy A9V39463?","answer":"The A9V39463 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V39463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V39463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}