{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9V71463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9V71463","canonicalUrl":"https://aoctrl.com/schneider/A9V71463","factsUrl":"https://aoctrl.com/api/mcp/products/A9V71463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V71463, 4P, 63 A, 30 mA, Type A-SI, instantaneous, 230 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9V71463 is an Acti9 Vigi iC60 add-on residual current device (RCD) — a 4-pole, 63 A unit with 30 mA earth-leakage sensitivity, Type A-SI (Super Immunised), instantaneous trip. It clips onto the DIN rail alongside the matching iC60 MCB to provide combined overcurrent and earth-leakage protection in a two-module stack. The voltage-independent trip mechanism means it clears a ground fault even if the line voltage collapses — a real advantage on circuits where a lost neutral could otherwise silence a conventional RCD. The 30 mA sensitivity catches leakage that would be hazardous to personnel; Type A-SI (Super Immunised) handles pulsed DC fault currents from electronics and resists nuisance tripping from high-frequency noise, so it's a good fit on circuits feeding VFDs, UPS units, or switching power supplies. Instantaneous trip means no intentional time delay — it clears within the standard RCD response window, which is what you want for shock protection but means you cannot coordinate it downstream of another instantaneous RCD. The 8/20 µs impulse withstand of 3000 A per IEC 61009-1 confirms it survives surge events without internal damage. Clip-on mounting to DIN rail, 7 x 9 mm pitches wide (63 mm). The screw connection to the adjacent MCB means you wire the phase and neutral through the MCB first, then the RCD picks up the outgoing side. Trip indicator on the front gives a local visual of whether it's the RCD that opened, which saves chasing the wrong device in a multi-way board.","metaTitle":"Schneider Electric A9V71463 Acti9 Vigi iC60, 4P, 63A, 30mA,","metaDescription":"Schneider Electric A9V71463 Acti9 Vigi iC60 add-on RCD. 4P, 63A, 30mA, Type A-SI, instantaneous. Obsolete — sourced to order against RFQ. EN/IEC 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"63 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","Quality labels":"CEBEC IMQ EAC NF","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230 V AC 50/60 Hz conforming to EN/IEC 61009-1 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6a9fb1a08ca2fff478f332dad2a6fd6.pdf","sourceUrl":"https://www.se.com/za/en/product/A9V71463/addon-residual-current-device-acti9-vigi-ic60-4p-63a-asi-type-instantaneous-30ma-230vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9V71463/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9V71463?","answer":"We source it to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — submit an RFQ and we will check the open market for you."},{"question":"What is the closest alternative to A9V71463?","answer":"The current Acti9 Vigi iC60 range carries the same 4P, 63 A, 30 mA, Type A-SI configuration in the same DIN-rail footprint. The mechanical and electrical swap should be direct — same width, same terminal layout, same voltage-independent trip — but verify the exact order code against your board's labelling before ordering."},{"question":"What compliance documentation does Schneider provide for A9V71463?","answer":"The part carries CEBEC, IMQ, EAC, and NF quality labels and is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. It also meets pollution degree 3 per IEC 60947-2. RoHS and REACH declarations are standard for the Acti9 range — request them with your RFQ if you need them on file."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9V71463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9V71463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}