{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9W12463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9W12463","canonicalUrl":"https://aoctrl.com/schneider/A9W12463","factsUrl":"https://aoctrl.com/api/mcp/products/A9W12463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 4P, 63 A, 100 mA, Type AC, clip-on DIN rail mount.","salesMarkdown":"It provides earth-leakage protection for a 4-pole (4P) circuit rated at 63 A, with a 100 mA sensitivity and Type AC detection for sinusoidal AC fault currents. The unit is voltage-independent, meaning it trips on residual current alone without needing a separate power supply — a key reliability feature for downstream protection. Mounts via clip-on onto a DIN rail, occupying 7 x 9 mm pitches (135 mm width total). The tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable on the downside, with a tightening torque of 3.5 N·m and a wire stripping length of 14 mm. The electrical connection to the upstream MCB is by screws, making it a straightforward add-on for panel builders integrating into an Acti9 distribution board. Rated operational voltage is 230/415 V AC at 50/60 Hz, with an insulation voltage of 500 V AC and impulse withstand of 6 kV per IEC 60947-2. Pollution degree 3 (conforming to IEC 60947-2) suits it for industrial control panels where conductive pollution may occur.","metaTitle":"Schneider Electric A9W12463 Vigi iC60, 4P 63A 100mA Type AC","metaDescription":"Schneider Electric A9W12463 Vigi iC60 add-on RCD block, 4P, 63 A, 100 mA, Type AC. Obsolete — sourced to order against RFQ. IEC/EN 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"135 mm","Height":"91 mm","Standards":"IEC 61009-1 EN 61009-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m","[In] rated current":"63 A","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230/415 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4d103f016a24e541760ecb9eb9a97085.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9W12463/vigi-ic60-earth-leakage-addon-block-4p-63a-100ma-ac-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9W12463/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9W12463?","answer":"The A9W12463 is available to order through independent distribution. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time."},{"question":"What are the key ratings of A9W12463?","answer":"The A9W12463 is a 4-pole add-on RCD rated at 63 A with 100 mA sensitivity, Type AC earth-leakage detection. It operates at 230/415 V AC, 50/60 Hz, and mounts on DIN rail."},{"question":"What standards does A9W12463 comply with?","answer":"It complies with IEC 61009-1 and EN 61009-1 for residual current operated circuit-breakers, and IEC 60947-2 for insulation and impulse withstand requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9W12463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9W12463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}