{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9W21263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9W21263","canonicalUrl":"https://aoctrl.com/schneider/A9W21263","factsUrl":"https://aoctrl.com/api/mcp/products/A9W21263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 63 A, 30 mA, Type A, clip-on DIN rail mount.","salesMarkdown":"## Lifecycle status — obsolete, sourced to order The A9W21263 is marked obsolete by Schneider Electric. For current BOM lines that specify this exact Acti9 Vigi iC60 2P 63A 30mA Type A add-on RCD, supply is through independent distribution — quoted to order against an RFQ, with availability and pricing confirmed at quote time. ## What it is — Acti9 Vigi iC60 add-on RCD The A9W21263 is a voltage-independent residual current device (RCD) from the Acti9 Vigi iC60 range. It clips onto the side of a compatible Acti9 iC60 MCB to add earth-leakage protection in a single modular width. Rated 63 A with 30 mA sensitivity, Type A (pulsating DC and sinusoidal AC fault detection), it sits downstream as an outgoer device in a 230/400 V AC 50/60 Hz network. The 30 mA sensitivity is the standard threshold for personnel protection against electric shock in residential and commercial final circuits. Type A detection covers the waveform shapes most common in modern electronics — single-phase rectified loads, switched-mode supplies, and variable-speed drives — so it is the default choice for mixed-load panels where pure sinusoidal (Type AC) would miss pulsating DC leakage. The 2P (two-pole) form factor matches a 2P MCB side-by-side. Tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible cable; strip length is 14 mm, tightening torque 3.5 N·m. IP20 finger-safe on the front, IP40 inside a modular enclosure. Depth of 74 mm and height of 91 mm fit standard distribution board cutouts. The trip indicator gives a local visual of RCD status — useful during fault isolation without breaking the seal. ## Protection ratings and standards compliance The 8/20 µs impulse withstand of 250 A (IEC 61009-1) means it survives common surge events without nuisance tripping. Instantaneous tripping (no intentional delay) provides fast disconnection for shock protection. Compliant with EN 61009-1 and IEC 61009-1 — the harmonized European standard for RCBOs and RCDs with integral overcurrent protection. The voltage-independent tripping mechanism means the RCD operates even if the neutral is lost, a safety advantage over electronically tripped units.","metaTitle":"Schneider Electric A9W21263 Acti9 Vigi iC60, 63A 30mA Type A","metaDescription":"Schneider Electric A9W21263 Acti9 Vigi iC60 add-on RCD, 2P, 63A, 30mA, Type A. Obsolete — sourced to order against an RFQ through independent distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"72 mm","Height":"91 mm","Standards":"EN 61009-1 IEC 61009-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m","[In] rated current":"63 A","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230/400 V AC 50/60 Hz conforming to EN 61009-1 230/240 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/08471ff5bb05ac24abfa3344b664ff53.pdf","sourceUrl":"https://www.se.com/th/en/product/A9W21263/addon-residual-current-device-acti9-vigi-ic60-2p-63a-30ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9W21263/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9W21263?","answer":"Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time. No stock figures or lead-time numbers are published here."},{"question":"What is the closest pin-compatible alternative to A9W21263?","answer":"No official successor or pin-compatible alternative is listed in the lifecycle record. For a BOM replacement, the closest functional match would be a current-production Acti9 Vigi iC60 add-on RCD with the same pole count, current rating, sensitivity, and type — verify mechanical compatibility with the existing MCB before ordering."},{"question":"What is A9W21263's listed range (Acti9) on this component line?","answer":"The A9W21263 belongs to the Schneider Electric Acti9 range, specifically the Vigi iC60 sub-family of add-on residual current devices. It is designed to clip onto Acti9 iC60 miniature circuit breakers."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9W21263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9W21263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}