{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9W22263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9W22263","canonicalUrl":"https://aoctrl.com/schneider/A9W22263","factsUrl":"https://aoctrl.com/api/mcp/products/A9W22263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 63 A, 100 mA, Type A, voltage independent, instantaneous, DIN rail clip-on.","salesMarkdown":"Rated 63 A with 100 mA sensitivity, Type A, 2-pole, it provides instantaneous earth leakage tripping for AC networks at 230/415 V, 50/60 Hz. The 63 A rated current (In) and 100 mA earth leakage sensitivity define the load and protection threshold. Voltage-independent tripping means the RCD operates without needing a separate power supply; it uses the fault current itself to trigger the mechanism, which makes it inherently fail-safe against loss of control voltage. Rated operational voltage of 230/415 V AC matches standard European single-phase and three-phase distribution. With an insulation voltage (Ui) of 500 V and impulse withstand (Uimp) of 6 kV, the device is coordinated for installation in panels with upstream surge protection. The 4-module width (72 mm, 4 x 9 mm pitches) occupies four DIN spaces — account for that when laying out the panel. IP20 body protection; IP40 inside a modular enclosure. Designed and certified to EN 61009-1 and IEC 61009-1, the standard for RCDs with integral overcurrent protection (though this is an add-on block, the MCB partner carries the overcurrent function). The 8/20 µs impulse withstand of 250 A per IEC 61009-1 confirms immunity to surge currents from lightning or switching transients.","metaTitle":"Schneider Electric A9W22263 Vigi iC60 RCD, 2P 63A 100mA Type","metaDescription":"Schneider Electric A9W22263 Acti9 Vigi iC60 add-on RCD, 2P, 63A, 100mA, Type A. Obsolete — sourced to order against RFQ. EN/IEC 61009-1. DIN rail.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"72 mm","Height":"91 mm","Standards":"EN 61009-1 IEC 61009-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m","[In] rated current":"63 A","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230/415 V AC 50/60 Hz conforming to EN 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5a99eb578815af26ea8a048dbbaee3ff.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9W22263/vigi-ic60-earth-leakage-addon-block-2p-63a-100ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9W22263/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9W22263 and get a price?","answer":"We source the A9W22263 through independent distribution channels. Submit an RFQ against this order code; availability and current pricing are confirmed at quote time."},{"question":"What is the A9W22263's earth leakage sensitivity and type?","answer":"100 mA sensitivity, Type A (detects sinusoidal AC and pulsating DC residual currents). Instantaneous trip, voltage-independent operation."},{"question":"What are the A9W22263's mounting and terminal specs?","answer":"Clip-on DIN rail mount, 4-module width (72 mm). Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; tightening torque 3.5 N·m; strip length 14 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9W22263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9W22263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}