{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9W22463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9W22463","canonicalUrl":"https://aoctrl.com/schneider/A9W22463","factsUrl":"https://aoctrl.com/api/mcp/products/A9W22463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9W22463, 4P, 63 A, Type A, 100 mA, instantaneous, 230/415 VAC.","salesMarkdown":"## Add-on RCD for iC60 MCBs, 4P 63A Type A The Schneider Electric A9W22463 is a 4-pole add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to clip directly onto the outgoing side of an iC60 miniature circuit breaker (MCB) with double terminals. It provides earth leakage protection for a 63 A circuit at 230/415 V AC, with a 100 mA sensitivity and Type A waveform detection — covering sinusoidal AC and pulsating DC fault currents up to 6 mA smooth DC, per IEC 61009-1. The trip is instantaneous, meaning no intentional time delay; the device reacts to the residual current as it occurs. The 63 A rated current (In) sets the maximum continuous load the RCD can carry; this matches a 63 A iC60 MCB upstream or downstream. The 100 mA sensitivity is higher than the typical 30 mA for personal shock protection — it is selected for equipment protection or where nuisance tripping from leakage on long cable runs must be avoided. Type A detection covers the majority of modern electronic loads (single-phase rectifiers, switched-mode supplies) that generate pulsating DC fault currents. Voltage-independent tripping means the RCD does not require a separate power supply or the line voltage to operate — it uses the fault energy itself to trip, so protection remains active even if the neutral is lost upstream. Clip-on mounting onto a DIN rail — the module occupies 7 x 9 mm pitches, so 63 mm of rail width. Tunnel-type terminals accept 1…35 mm² rigid or 1…25 mm² flexible cable; tightening torque is 3.5 N·m. The connection to the iC60 MCB is by screws, which means the RCD bolts mechanically and electrically to the MCB's double-terminal busbar — no additional wiring between MCB and RCD. IP20 body with IP40 modular enclosure is standard for panel mounting; not rated for washdown. ## Standards and environmental Designed and certified to EN 61009-1 and IEC 61009-1 for RCBOs — this is the product standard for combined overcurrent and residual current devices, though this is an add-on RCD, not a combined unit. Rated impulse withstand voltage (Uimp) is 6 kV; insulation voltage (Ui) is 500 V AC. Operating temperature range is -25…60 °C; storage from -40…85 °C. The 8/20 µs impulse withstand of 250 A confirms the device survives surge currents from lightning or switching transients without nuisance tripping.","metaTitle":"Schneider Electric A9W22463 Vigi iC60 4P 63A 100mA Type A RC","metaDescription":"Schneider Electric A9W22463 Acti9 Vigi iC60 add-on RCD, 4P, 63A, 100mA, Type A, instantaneous, 230/415VAC. Active production. Sourced to order. EN/IEC 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"135 mm","Height":"91 mm","Standards":"EN 61009-1 IEC 61009-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m","[In] rated current":"63 A","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230/415 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/709d73ac0a0f59d6271407a3318ea53e.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9W22463/addon-residual-current-device-acti9-vigi-ic60-4p-63a-a-type-instantaneous-100ma-230-415vac-for-ic60-double-terminal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9W22463/alternatives.json"},"ai":{"faq":[{"question":"What is the A9W22463's earth leakage sensitivity and type?","answer":"The A9W22463 has a 100 mA sensitivity and Type A earth leakage protection — it detects sinusoidal AC and pulsating DC fault currents, suitable for electronic loads."},{"question":"What is the A9W22463's depth?","answer":"The A9W22463 has a depth of 74 mm, width of 135 mm, and height of 91 mm."},{"question":"Where can I buy the A9W22463?","answer":"The A9W22463 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for the A9W22463?","answer":"The A9W22463 is certified to EN 61009-1 and IEC 61009-1, with pollution degree 3 per IEC 60947-2 and IP20/IP40 protection per IEC 60529. The manufacturer provides declarations of conformity and test reports for these standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9W22463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9W22463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}