{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9W25463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9W25463","canonicalUrl":"https://aoctrl.com/schneider/A9W25463","factsUrl":"https://aoctrl.com/api/mcp/products/A9W25463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 earth leakage add-on block, 4P, 63A, 300mA, type A selective, voltage independent, DIN rail clip-on.","salesMarkdown":"The A9W25463 is a Schneider Electric Acti9 Vigi iC60 earth leakage add-on block — a 4-pole, 63 A rated, 300 mA sensitivity, type A selective residual current device (RCD) that clips onto the downstream side of an iC60 MCB. It is voltage independent, meaning the residual current detection circuit does not rely on the line voltage to operate; tripping energy comes from the fault itself. This makes it suitable for circuits where voltage may be lost during a fault condition. Rated operational voltage is 400 V AC at 50/60 Hz per EN 61009-1, with a 230/415 V AC range per IEC 61009-1. Insulation voltage is 500 V AC, impulse withstand 6 kV. The selective time delay (marked S) coordinates with downstream RCDs to prevent nuisance tripping on transient earth faults — the upstream unit holds off long enough for the downstream device to clear a fault first. Mounts via clip-on to DIN rail, occupying 7 modules of 9 mm pitch (135 mm width). ## Integration & wiring This add-on block screws directly to the outgoing side of an iC60 MCB. The mechanical interlock prevents the block from being mounted without the MCB, and the trip indicator on the block gives local visual status. The 8/20 µs impulse withstand rating of 3000 A per IEC 61009-1 means the internal surge suppression handles typical lightning-induced transients without nuisance tripping.","metaTitle":"A9W25463 Vigi iC60 earth leakage add-on block 4P 63A 300mA t","metaDescription":"Obsolete A9W25463 Acti9 Vigi iC60 earth leakage add-on block. 4P 63A 300mA type A selective. IEC 61009-1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"135 mm","Height":"91 mm","Standards":"IEC 61009-1 EN 61009-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m","[In] rated current":"63 A","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz conforming to EN 61009-1 230/415 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d0b0c9cf6c26d0e0d2d44553901764d6.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9W25463/vigi-ic60-earth-leakage-addon-block-4p-63a-300ma-a-type-selective/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9W25463/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9W25463?","answer":"The A9W25463 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm price and lead time."},{"question":"What are the key ratings of A9W25463?","answer":"4 poles, 63 A rated current, 300 mA earth leakage sensitivity, type A selective (time-delayed), voltage independent tripping. Rated operational voltage 400 V AC 50/60 Hz, insulation voltage 500 V AC, impulse withstand 6 kV. Pollution degree 3."},{"question":"What compliance standards does A9W25463 meet?","answer":"IEC 61009-1 and EN 61009-1 for residual current operated circuit-breakers with integral overcurrent protection. IP20 per IEC 60529 (IP40 in modular enclosure). 8/20 µs impulse withstand 3000 A per IEC 61009-1."},{"question":"What is the physical size of A9W25463?","answer":"Width 135 mm (7 modules of 9 mm pitch), height 91 mm, depth 74 mm. Clip-on DIN rail mounting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9W25463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9W25463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}