{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9W26463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9W26463","canonicalUrl":"https://aoctrl.com/schneider/A9W26463","factsUrl":"https://aoctrl.com/api/mcp/products/A9W26463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 4P, 63 A, 500 mA sensitivity, Type A, 230/415 V AC, 50/60 Hz, clip-on DIN rail mount, IP20/IP40.","salesMarkdown":"The A9W26463 is a Schneider Electric Acti9 Vigi iC60 add-on residual current device (RCD) — 4 poles, rated 63 A, with 500 mA earth-leakage sensitivity, Type A. It clips onto the side of a compatible iC60 MCB on a DIN rail, occupying 7 x 9 mm pitches (135 mm wide). The unit is voltage-independent: it trips on residual current alone, no auxiliary supply needed. That 500 mA sensitivity is typical for feeder or submain protection where a lower threshold would cause nuisance tripping from leakage in long cable runs or multiple loads. The screw terminal tunnel accepts 1 to 35 mm² rigid or 1 to 25 mm² flexible cable; strip length is 14 mm, torque to 3.5 N·m. The unit is an outgoer device, meaning it sits downstream of the MCB in the distribution board. Pollution degree 3 (IEC 60947-2) means it's rated for the conductive-dust and humidity environment inside a standard industrial panel. IP20 on the body, IP40 inside a modular enclosure — so it's not for washdown areas, but fine inside a cabinet. Rated operational voltage 230/415 V AC, 50/60 Hz, with insulation voltage 500 V AC and impulse withstand 6 kV. The instantaneous trip characteristic means no intentional delay — it clears a fault within the natural response time of the voltage-independent mechanism. The 8/20 µs impulse withstand of 250 A (per IEC 61009-1) confirms it survives surge events typical of AC mains without nuisance tripping.","metaTitle":"A9W26463 Vigi iC60 4P 63A 500mA Type A RCD, Obsolete","metaDescription":"A9W26463 Acti9 Vigi iC60 add-on RCD, 4P 63A 500mA Type A, 230/415 V AC. Obsolete per manufacturer; sourced to order against RFQ. IEC 61009-1, EN 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"135 mm","Height":"91 mm","Standards":"IEC 61009-1 EN 61009-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m","[In] rated current":"63 A","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"500 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type A","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230/415 V AC 50/60 Hz conforming to IEC 61009-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/69fea5799d3078b23fb17efecce4b57a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9W26463/vigi-ic60-earth-leakage-addon-block-4p-63a-500ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9W26463/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9W26463?","answer":"The A9W26463 is an Acti9 Vigi iC60 add-on RCD. A current-production Vigi iC60 with the same pole count (4P), sensitivity (500 mA), and Type A characteristic will be a functional equivalent — same DIN footprint, same clip-on interface to the iC60 MCB. Check the current Acti9 catalog for the exact order code matching your voltage and frequency."},{"question":"Where can I buy A9W26463?","answer":"We source the A9W26463 to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time. Submit a request for a quote."},{"question":"What compliance documentation does A9W26463 have?","answer":"The A9W26463 is certified to IEC 61009-1 and EN 61009-1. The manufacturer's standard documentation package includes the declaration of conformity for these standards. RoHS and REACH compliance is standard for Acti9 products of this era."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9W26463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9W26463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}