{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9XMC1D3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9XMC1D3","canonicalUrl":"https://aoctrl.com/schneider/A9XMC1D3","factsUrl":"https://aoctrl.com/api/mcp/products/A9XMC1D3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric PowerTag Control, input/output module A9XMC1D3, 1 dry contact input 230 V AC 2 mA, 1 configurable relay output 230 V 0.01-2 A AC, clip-on DIN rail, 2 x 9 mm pitches, white (RAL 9003).","salesMarkdown":"The Schneider Electric A9XMC1D3 is a PowerTag Control input/output module — a compact, clip-on DIN-rail slice that adds one dry-contact sense point and one programmable relay output to an Acti9 PowerTag energy-monitoring network. It lives in the same 18 mm wide footprint as the rest of the PowerTag family, so it slots into an existing PowerTag Link concentrator chain without extra panel real estate. The single digital input is rated for dry contacts at 230 V AC, 2 mA, and the output is a configurable NO/NC relay rated 230 V AC, 0.01 to 2 A. That output rating means it switches small pilot-duty loads — indicator lamps, contactor coils, signal lamps — not motor loads directly. The 100,000-cycle mechanical durability is typical for a signal relay; plan for it in a control scheme, not a high-cycle power-switching role. The IP20 casing and IP40 front face are standard for a dry indoor enclosure; no washdown rating here. ## Wiring and integration The module occupies two 9 mm pitches, so 18 mm of rail width. Tunnel-type terminals: top connection accepts 1 to 16 mm² rigid, bottom accepts 1 to 6 mm² rigid. Wire stripping lengths are 14 mm for the top (power supply) and 9 mm for the bottom (I/O). Tightening torque: 2 N·m for the top power terminals, 1 N·m for the bottom I/O terminals. The input is a dry-contact type at 230 V AC, 2 mA. State 0 guaranteed at ≤ 0.5 mA, state 1 at ≥ 2 mA — so a standard pushbutton or limit switch with a 2 mA wetting current will be read reliably. The output is a relay with NO/NC programmable logic, configurable through the PowerTag Link concentrator.","metaTitle":"Schneider Electric A9XMC1D3 PowerTag Control IO Module, 230V","metaDescription":"Schneider Electric A9XMC1D3 PowerTag Control IO module. 1 DI dry contact 230V AC 2mA, 1 relay output 0.01-2A AC. Clip-on DIN rail. IP20. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"62 mm","Range":"PowerTag","Width":"18 mm","Colour":"White (RAL 9003)","Height":"85 mm","Material":"PA6 GF30","Standards":"EN/IEC 61010-1 ETSI EN 300 328 EN/IEC 62479 ETSI EN 301 489-17 ETSI EN 301 489-1 EN/IEC 61010-2-201 EN/IEC 61326-1","Input type":"Dry contact 230 V AC 2 mA","Output type":"Dry contact 230 V 0.01...2 A AC","9 Mm Pitches":"2","Product name":"PowerTag Control","Mounting mode":"Clip-on","Fire resistance":"960 °C / 30 s conforming to UL 94 V0","Output function":"NO/NC programmable","lifecycle_stage":"current","Impulse duration":"300 ms by default - 0 ms, + 300 ms","Local signalling":"Green, orange and red LED for product status","Mounting support":"DIN rail","Pollution degree":"3","Device short name":"PowerTag C IO 230V","Network frequency":"50/60 Hz","Relative humidity":"0...93 % at 40 °C conforming to IEC 60068-2-78","Tightening torque":"Power supply: 2 N.m top Digital input/output: 1 N.m bottom","Operating altitude":"0...2000 m","Digital input number":"1","Discrete output type":"Configurable relay logic","Overvoltage category":"III conforming to IEC 61010-1","Digital output number":"1","Mechanical durability":"100000 cycles for output","Wire stripping length":"14 mm for top connection 9 mm for bottom connection","Time between 2 impulse":"100 ms minimum - tolerance: - 0 ms, + 300 ms","Connections - terminals":"Tunnel type terminals (top) - 1 cable(s) 1...16 mm² (AWG 18...AWG 16) - rigid Tunnel type terminals (top) - 1 cable(s) 0.5...10 mm² (AWG 21...AWG 8) - flexible Tunnel type terminals (bottom) - 1 cable(s) 1...6 mm² (AWG 18...AWG 10) - rigid Tunnel type terminals (bottom) - 1 cable(s) 0.5...4 mm² (AWG 21...AWG 12) - flexible Tunnel type terminals (bottom) - 1 cable(s) 0.5...4 mm² (AWG 21...AWG 12) - flexible with ferrule Tunnel type terminals (bottom) - 2 cable(s) 1.5...2.5 mm² (AWG 16...AWG 14) - rigid Tunnel type terminals (bottom) - 2 cable(s) 1.5...2.5 mm² (AWG 16...AWG 14) - flexible","IK degree of protection":"IK05","IP degree of protection":"IP20 casing: conforming to IEC 60529 IP40 front face: conforming to IEC 60529","Power consumption in VA":"2 VA","Product or component type":"Input and ouput module","[Us] rated supply voltage":"230 V AC (+/- 20 %)","Concentrator compatibility":"Acti9 PowerTag Link C Wiser IP module Acti9 PowerTag Link Acti9 PowerTag Link HD","Current state 0 guaranteed":"<= 0.5 mA (digital input)","Voltage state 0 guaranteed":"= 2 mA (digital input)","Voltage state 1 guaranteed":">= 164 V for digital input","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$165.89 – $184.41","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nz/en/product/A9XMC1D3/powertag-c-io-230v-digital-input-output-module/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9XMC1D3/alternatives.json"},"ai":{"faq":[{"question":"What is the A9XMC1D3 used for?","answer":"The A9XMC1D3 is a PowerTag Control I/O module used to add one dry-contact digital input and one programmable relay output to an Acti9 PowerTag energy-monitoring network, typically in a DIN-rail control panel for monitoring and switching pilot-duty loads."},{"question":"Where can I buy A9XMC1D3?","answer":"The A9XMC1D3 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does A9XMC1D3 carry?","answer":"The module is certified to EN/IEC 61010-1, EN/IEC 61326-1, ETSI EN 300 328, ETSI EN 301 489-1, ETSI EN 301 489-17, EN/IEC 61010-2-201, and EN/IEC 62479. Fire resistance is UL 94 V0 at 960 °C for 30 s."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9XMC1D3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9XMC1D3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}