{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Y70640","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Y70640","canonicalUrl":"https://aoctrl.com/schneider/A9Y70640","factsUrl":"https://aoctrl.com/api/mcp/products/A9Y70640","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iCG40 add-on residual current device, A9Y70640, 40 A, 30 mA, Type A, 1P+N, DIN rail clip-on.","salesMarkdown":"The 1P+N pole arrangement with neutral on the left fits standard single-phase group incomer positions in Acti9 distribution boards. 40 A rated current and 30 mA sensitivity are the two numbers that decide whether this RCD matches your branch circuit. Type A detection covers both sinusoidal AC and pulsating DC — common for circuits feeding electronics, appliances, or LED drivers that generate half-wave rectified leakage. Voltage-independent tripping means the RCD operates without needing a power supply from the line — it uses the fault energy itself to trip, so protection remains active even if the neutral is lost upstream. Instantaneous time delay (no intentional delay) means it trips within the standard 300 ms window for 1× IΔn, as required by EN/IEC 61009-2-1. Rated insulation voltage 400 V AC and impulse withstand 4 kV (Ui and Uimp) confirm the device is rated for 230/400 V TN or TT systems. Clip-on mounting on DIN rail — snaps onto the rail without tools. The module is 36 mm wide (2 x 9 mm pitches), 102.5 mm tall, 74 mm deep. Tunnel-type terminals accept 1…16 mm² rigid or 1…10 mm² flexible cable; tighten to 2 N·m. IP20 on the device body (finger-safe), IP40 inside the modular enclosure — suitable for installation in a distribution board with a cover. Ambient operating range -25…60 °C, storage -40…85 °C, altitude up to 2000 m. Relative humidity 95 % at 55 °C.","metaTitle":"Schneider Electric A9Y70640 Acti9 Vigi iCG40 RCD, 40 A, 30 m","metaDescription":"Schneider Electric A9Y70640 Acti9 Vigi iCG40 add-on residual current device. 40 A rated current, 30 mA sensitivity, Type A, 1P+N, DIN rail mount. Current production. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"102.5 mm","Standards":"EN/IEC 61009-2-1","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 Vigi iCG40","Mounting mode":"Clip-on","Quality labels":"IMQ","lifecycle_stage":"current","Local signalling":"Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 61009-2-1","Device short name":"Vigi iCG40","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top","Operating altitude":"2000 m","[In] rated current":"40 A","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top connection","Connections - terminals":"Tunnel type terminal top 1...16 mm² rigid Tunnel type terminal top 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Group incomer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","[Ui] rated insulation voltage":"400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 61009-2-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$346.95","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9Y70640/addon-residual-current-device-acti9-vigi-icg40-1p+n-40a-a-type-instantaneous-30ma-230vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Y70640/alternatives.json"},"ai":{"faq":[{"question":"What is A9Y70640's listed depth (74 mm) on this component line?","answer":"The A9Y70640 has a depth of 74 mm, width of 36 mm, and height of 102.5 mm."},{"question":"What is A9Y70640's listed range (Acti9) on this component line?","answer":"The A9Y70640 belongs to the Schneider Electric Acti9 range, specifically the Vigi iCG40 series of add-on residual current devices."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Y70640","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Y70640 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}