{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Y71625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Y71625","canonicalUrl":"https://aoctrl.com/schneider/A9Y71625","factsUrl":"https://aoctrl.com/api/mcp/products/A9Y71625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iCG40 add-on residual current device, 1P+N, 25 A, 300 mA Type A, instantaneous, voltage independent, DIN rail clip-on, 2-module width.","salesMarkdown":"It provides earth-leakage protection for the downstream circuit without replacing the existing MCB — a modular approach that keeps the breaker's overcurrent and short-circuit ratings intact while adding the RCD function. Rated 25 A continuous current with 300 mA Type A earth-leakage sensitivity, it trips instantaneously on fault and is voltage independent, meaning it operates even if the supply voltage collapses during a ground fault. The 300 mA sensitivity is a common choice for group incomer or sub-distribution protection where nuisance tripping from normal leakage (cable capacitance, filter Y-caps) must be avoided. The instantaneous trip characteristic means no intentional time delay; the RCD clears within 200 ms per EN/IEC 61009-2-1, which is the standard for this class. Voltage-independent tripping is a reliability advantage: the RCD stores enough energy from the fault current itself to open the contacts, so a lost neutral or sagging supply won't disable protection. The device occupies 2 x 9 mm pitches (18 mm width), matching the 1P+N module footprint. It connects to the upstream MCB via screw terminals — tunnel-type terminals accepting 1–16 mm² rigid or 1–10 mm² flexible conductors, tightened to 2 N·m. A fault-indication flag provides local visual status.","metaTitle":"Schneider Electric A9Y71625 Acti9 Vigi iCG40, 25 A 300 mA Ty","metaDescription":"Schneider Electric A9Y71625 Acti9 Vigi iCG40 add-on RCD. 25 A rated current, 300 mA Type A earth-leakage, instantaneous, voltage independent. DIN rail mount. Sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"102.5 mm","Standards":"EN/IEC 61009-2-1","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 Vigi iCG40","Mounting mode":"Clip-on","Quality labels":"IMQ","lifecycle_stage":"current","Local signalling":"Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 61009-2-1","Device short name":"Vigi iCG40","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top","Operating altitude":"2000 m","[In] rated current":"25 A","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top connection","Connections - terminals":"Tunnel type terminal top 1...16 mm² rigid Tunnel type terminal top 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Group incomer","Earth-leakage sensitivity":"300 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","[Ui] rated insulation voltage":"400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 61009-2-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$251.48","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9Y71625/addon-residual-current-device-acti9-vigi-icg40-1p+n-25a-a-type-instantaneous-300ma-230vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Y71625/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9Y71625 and how do I get a price?","answer":"The A9Y71625 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing."},{"question":"What is A9Y71625's listed depth (74 mm) on this component line?","answer":"The A9Y71625 has a depth of 74 mm, which is standard for the Acti9 Vigi iCG40 add-on RCD module."},{"question":"What is A9Y71625's listed range (Acti9) on this component line?","answer":"The A9Y71625 belongs to the Schneider Electric Acti9 range, specifically the Vigi iCG40 series of add-on residual current devices."},{"question":"What compliance documentation does this brand provide for A9Y71625 (RoHS, REACH, UL, IEC)?","answer":"The A9Y71625 is certified to EN/IEC 61009-2-1 and carries the IMQ quality label. It is designed for 230 V AC 50/60 Hz networks with pollution degree 3 per the same standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Y71625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Y71625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}