{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Z11280","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Z11280","canonicalUrl":"https://aoctrl.com/schneider/A9Z11280","factsUrl":"https://aoctrl.com/api/mcp/products/A9Z11280","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 80 A, 30 mA Type AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9Z11280 is an Acti9 iID 2-pole residual current circuit breaker (RCCB) rated 80 A with 30 mA earth-leakage sensitivity, Type AC, designed for clip-on mounting on DIN rail. It protects against sinusoidal AC fault currents in residential and commercial distribution boards where the load is predominantly resistive or inductive with minimal DC component. The 80 A rated current ([In]) means this RCCB can carry continuous load up to 80 A without nuisance tripping — sized for sub-mains or heavy feeder circuits, not final sub-circuits. The 30 mA sensitivity catches leakage currents that would otherwise go undetected until someone becomes part of the path; it's the standard threshold for personnel protection in most IEC-based codes. Type AC detection means it only responds to sinusoidal AC residual currents — no pulsed DC or smooth DC. If the downstream load includes VFDs, UPS, or LED drivers that generate DC leakage, you need a Type A or Type B device instead. Breaking capacity is rated Idm 1500 A and Im 1500 A per EN/IEC 61008-1, with a conditional short-circuit current (SCCR) of 10 kA when backed by an upstream overcurrent device. The 10 kA figure tells you the maximum prospective fault current this RCCB can survive under test conditions with a suitable MCB or fuse ahead of it. In a panel with available fault current above 10 kA, the RCCB must be coordinated with a current-limiting breaker or the panel's SCCR must be re-evaluated. Insulation voltage (Ui) is 500 V AC, impulse withstand (Uimp) is 6 kV. Neutral is on the left. IP20 on the device body (finger-safe), IP40 inside a modular enclosure. The electrical durability is 10,000 cycles under AC-1 (resistive) load; mechanical durability is 20,000 cycles — figures that matter if the RCCB is used as a manual switch, not just as a protective device.","metaTitle":"Schneider Electric A9Z11280 Acti9 iID RCCB, 80 A 30 mA Type","metaDescription":"Schneider Electric A9Z11280 Acti9 iID 2P RCCB, 80 A rated current, 30 mA sensitivity, Type AC, 10 kA SCCR. Clip-on DIN rail. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61008-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","Surge current":"250 A","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"AC-1: 10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Earth-leakage sensitivity":"30 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9Z11280/acti-9-iid-rccb-2p-80a-30ma-type-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Z11280/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9Z11280 and how do I get a price?","answer":"The A9Z11280 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is A9Z11280's listed depth?","answer":"The A9Z11280 has a depth of 73 mm."},{"question":"What is A9Z11280's listed range?","answer":"The A9Z11280 belongs to the Acti9 range from Schneider Electric."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Z11280","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Z11280 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}