{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Z12263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Z12263","canonicalUrl":"https://aoctrl.com/schneider/A9Z12263","factsUrl":"https://aoctrl.com/api/mcp/products/A9Z12263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 63 A, 100 mA, Type AC, 220-240 V AC, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9Z12263 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, 63 A device with 100 mA earth-leakage sensitivity, Type AC, rated for 220-240 V AC at 50/60 Hz. The 100 mA sensitivity makes it a good fit for general-purpose circuits where nuisance tripping from normal leakage is a concern — think sub-mains, feeders, or whole-floor protection rather than individual socket outlets. Rated at 63 A continuous, this RCCB handles the full load of a typical residential or light-commercial sub-main without derating at the standard 30 °C ambient. The 100 mA sensitivity (Type AC) detects sinusoidal AC earth faults only — not pulsed DC or smooth DC, so it is not suitable for circuits with VFDs, UPS systems, or EV chargers that generate non-sinusoidal leakage. The 2-pole (2P) form factor with neutral on the left occupies 4 x 9 mm pitches (36 mm wide) on the DIN rail — a standard two-module width for a double-pole RCCB. The voltage-independent tripping mechanism means the device does not need an auxiliary supply to detect leakage; it trips purely on the residual current itself, which is a reliability advantage in installations where neutral loss could otherwise leave a voltage-dependent RCCB blind. The 14 mm wire stripping length and 3.5 N·m tightening torque are standard for this class.","metaTitle":"Schneider Electric A9Z12263 Acti9 iID RCCB, 63 A, 100 mA, Ty","metaDescription":"Schneider Electric A9Z12263 Acti9 iID residual current circuit breaker (RCCB). 63 A rated current, 100 mA sensitivity, Type AC, 2P, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61008-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"AC-1: 15000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Earth-leakage sensitivity":"100 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/id/en/product/A9Z12263/residual-current-circuit-breaker-rccb-acti9-iid-2p-63a-ac-type-100ma-double-terminal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Z12263/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9Z12263 and how is it quoted for volume purchases?","answer":"This part is supplied through independent distribution channels and is quoted to order against an RFQ. Submit a request with your target quantity and schedule for a firm price and lead time."},{"question":"What is A9Z12263's listed depth (73 mm) on this component line?","answer":"The A9Z12263 has a depth of 73 mm, a width of 36 mm (4 x 9 mm pitches), and a height of 91 mm — standard two-module RCCB dimensions for DIN-rail enclosures."},{"question":"What is A9Z12263's listed range (Acti9) on this component line?","answer":"The A9Z12263 belongs to the Schneider Electric Acti9 range, specifically the Acti9 iID series of residual current circuit breakers."},{"question":"What compliance documentation does this brand provide for A9Z12263 (RoHS, REACH, UL, IEC)?","answer":"The A9Z12263 is designed and tested to EN/IEC 61008-1. Standard compliance documentation (declaration of conformity, CE marking) is available upon request. Specific RoHS/REACH declarations can be provided at quote time."},{"question":"Where can I buy A9Z12263?","answer":"The A9Z12263 is available to order through our distribution channel. Submit an RFQ for current pricing and lead time — we quote each request individually based on quantity and delivery window."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Z12263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Z12263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}