{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Z24280","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Z24280","canonicalUrl":"https://aoctrl.com/schneider/A9Z24280","factsUrl":"https://aoctrl.com/api/mcp/products/A9Z24280","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, A9Z24280, Residual Current Circuit Breaker (RCCB), 2P, 80 A, 300 mA, Type A, 220-240 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9Z24280 is an Acti9 iID residual current circuit breaker (RCCB) — a voltage-independent, 2-pole device rated for 80 A continuous load at 220-240 V AC, 50/60 Hz. It trips on earth-leakage faults at 300 mA sensitivity, Type A waveform detection, meaning it catches pulsating DC residual currents from rectified loads like VFDs, switching power supplies, and LED drivers. The 300 mA threshold is typical for circuit protection where a 30 mA unit would nuisance-trip on normal leakage from long cable runs or filter caps. The 80 A rated current (In) sets the continuous load limit through the main contacts — sized for a submain feeder or a large single load, not a final subcircuit. The 300 mA earth-leakage sensitivity is an equipment-protection or fire-protection threshold, not personnel protection (that would be 30 mA or lower). Type A detection means it sees the pulsating DC waveforms common in modern electronic loads; a plain AC-type RCCB would miss those and leave the fault live. Breaking capacity: Idm 1500 A and Im 1500 A — this is the RCCB's own fault-clearing capability for earth faults. The conditional short-circuit rating is 10 kA (IEC 61008-1), meaning it can withstand a 10 kA prospective fault current when backed by an upstream overcurrent device (MCB or fuse) sized per the manufacturer's coordination table. Without that backup, the RCCB's own contacts are rated for 1500 A make-break. Impulse withstand: 8/20 µs surge, 250 A — this is the electromagnetic compatibility rating per EN/IEC 61008-1. It tells you the RCCB will not nuisance-trip on a lightning or switching surge up to that energy. Neutral on the left. The double-terminal design accepts up to 35 mm² rigid on the front, 25 mm² flexible with ferrule — enough for the 80 A feed conductors. Torque terminals to 3.5 N·m. Strip length 14 mm.","metaTitle":"Schneider Electric A9Z24280 Acti9 iID RCCB, 80 A, 300 mA, 2P","metaDescription":"Schneider Electric A9Z24280 Acti9 iID RCCB, 80 A rated current, 300 mA sensitivity, Type A, 2-pole, 220-240 V AC. EN/IEC 61008-1. Available to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61008-1 EN/IEC 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"AC-1: 10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9Z24280/residual-current-circuit-breaker-rccb-acti9-iid-2p-80a-a-type-300ma-double-terminal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Z24280/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9Z24280 and how do I get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is A9Z24280's listed depth?","answer":"The listed depth is 73 mm."},{"question":"What compliance documentation does this brand provide for A9Z24280?","answer":"The device is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1. The Acti9 range typically carries CE, UKCA, and EAC markings; specific RoHS/REACH declarations are available from the manufacturer upon request."},{"question":"What is the closest alternative to A9Z24280 in the Acti9 iID family?","answer":"Within the same Acti9 iID range, the closest sibling is a 2-pole, 80 A, 300 mA unit. The deciding factor is typically the sensitivity (30 mA vs 300 mA) or the pole count (2P vs 4P) — the A9Z24280 is the 2P 300 mA variant. If you need personnel protection, step down to the 30 mA version in the same form factor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Z24280","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Z24280 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}