{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Z26480","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Z26480","canonicalUrl":"https://aoctrl.com/schneider/A9Z26480","factsUrl":"https://aoctrl.com/api/mcp/products/A9Z26480","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, A9Z26480, 4P RCCB, 80 A, 500 mA, Type A, instantaneous, 380-415 V AC, 10 kA SCCR.","salesMarkdown":"The A9Z26480 is a Schneider Electric Acti9 iID 4-pole residual current circuit breaker (RCCB) rated at 80 A with 500 mA earth-leakage sensitivity. The instantaneous trip (no intentional time delay) means it clears a ground fault within the natural operating time of the RCCB mechanism, so it is suited for final-circuit protection rather than selective coordination with upstream delayed RCDs. The rated conditional short-circuit current is 10 kA — this is the prospective fault current the RCCB can withstand when backed by an upstream overcurrent protective device (typically a MCB or fuse rated at or below the SCCR). For a panel feeding a 10 kA fault level at the point of installation, this RCCB is within its rated capacity; above that level, coordination with a current-limiting device is required. The 4P configuration (four poles switched, neutral left) makes this unit suitable for three-phase four-wire systems where all live conductors including the neutral are disconnected on a fault. The clip-on DIN-rail mount and 72 mm width (8 x 9 mm pitches) fit standard distribution-board profiles; the white housing is the Acti9 family colour. ## Deployment context IP20 and IP40 ratings apply. Pollution degree 3 rating. Rated impulse withstand voltage of 6 kV and insulation voltage of 500 V AC. Designed and certified to EN/IEC 61008-1 and EN/IEC 61008-2-1, the governing standards for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses. The 8/20 µs impulse withstand of 250 A confirms electromagnetic compatibility with typical surge events on the mains supply.","metaTitle":"A9Z26480 Acti9 iID RCCB, 80 A, 500 mA, 4P, Type A","metaDescription":"Schneider Electric A9Z26480 Acti9 iID RCCB, 80 A rated current, 500 mA sensitivity, 4P, Type A, instantaneous. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61008-1 EN/IEC 61008-2-1","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"AC-1: 10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Earth-leakage sensitivity":"500 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/A9Z26480/residual-current-circuit-breaker-rccb-acti9-iid-4p-80a-a-type-500ma-double-terminal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Z26480/alternatives.json"},"ai":{"faq":[{"question":"What is A9Z26480's listed depth?","answer":"The A9Z26480 has a depth of 73 mm, with a width of 72 mm and height of 91 mm."},{"question":"What compliance documentation does Schneider Electric provide for A9Z26480?","answer":"The A9Z26480 is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1. Standard Schneider Electric documentation includes a CE declaration of conformity and the product datasheet. RoHS and REACH compliance is standard for the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Z26480","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Z26480 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}