{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Z73463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Z73463","canonicalUrl":"https://aoctrl.com/schneider/A9Z73463","factsUrl":"https://aoctrl.com/api/mcp/products/A9Z73463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 4 poles, 63 A, 100 mA sensitivity, Type AC, selective, 380-415 V AC, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9Z73463 is an Acti9 iID residual current circuit breaker (RCCB) — 4 poles, rated 63 A continuous, with 100 mA earth-leakage sensitivity and a selective (time-delayed) trip characteristic. It is designed for AC networks at 380-415 V, 50/60 Hz, and clips onto a DIN rail for panel mounting. The 100 mA sensitivity and selective delay make this unit suitable for downstream feeder protection where coordination with upstream RCDs is required — the delay prevents nuisance tripping on transient leakage or short-duration faults, so only the faulted branch clears. Rated conditional short-circuit current is 10 kA, and the impulse withstand is 3000 A (8/20 µs wave) per EN/IEC 61008-1, so it handles typical industrial fault levels without upstream reinforcement. Clip-on mounting on DIN rail, 72 mm wide (8 x 9 mm pitches), neutral on the left. Terminals accept double front or back entry up to 35 mm² rigid or 25 mm² flexible; stripping length 14 mm, torque to 3.5 N·m.","metaTitle":"Schneider Electric A9Z73463 Acti9 iID RCCB, 4P 63A 100mA Typ","metaDescription":"Schneider Electric A9Z73463 Acti9 iID RCCB, 4 poles, 63 A rated current, 100 mA sensitivity, Type AC, selective time delay. 10 kA SCCR, DIN rail mount. Sourced to order against RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61008-1","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"AC-1: 15000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Earth-leakage sensitivity":"100 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"380...415 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Selective","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9Z73463/acti-9-iid-rccb-4p-63a-100ma-s-type-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Z73463/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9Z73463?","answer":"Submit an RFQ through this listing. The part is sourced to order; pricing and stock levels are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to A9Z73463 in this component family?","answer":"Within the Acti9 iID family, the key variant differences are poles, sensitivity, and time delay. For a 4-pole 63 A RCCB with a different sensitivity (e.g., 30 mA or 300 mA) or instantaneous trip, the same physical footprint and terminal arrangement apply — but the selective delay is specific to this order code."},{"question":"What compliance documentation does this brand provide for A9Z73463?","answer":"The part is certified to EN/IEC 61008-1. Contact Schneider Electric for RoHS/REACH declarations; the evidence does not list those documents directly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Z73463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Z73463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}