{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ABE7S16E2M0E","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ABE7S16E2M0E","canonicalUrl":"https://aoctrl.com/schneider/ABE7S16E2M0E","factsUrl":"https://aoctrl.com/api/mcp/products/ABE7S16E2M0E","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon ABE7 series, ABE7S16E2M0E, solid state input relay sub-base, 16 inputs, 230 V AC sensor end, 24 V DC PLC end.","salesMarkdown":"The ABE7S16E2M0E is a solid state input relay sub-base from the Modicon ABE7 range, providing 16 input channels that accept 230/240 V AC from the sensor side and interface with a 24 V DC PLC end. It is designed to isolate field sensors from the controller, with a response time of ≤ 20 ms from state 1 to 0. The sensor end is rated for 230/240 V AC 50/60 Hz, with a guaranteed state 1 voltage of ≥ 164 V and a state 0 current of ≤ 4.5 mA. This means it reliably detects a '1' signal from standard 230 V AC sensors (e.g., proximity or photoelectric) even with line voltage sag, and a '0' when the sensor leakage is below that threshold. The PLC end operates on 19...30 V DC, with a maximum switching current of 15 mA and a minimum of 1 mA, so it can drive a standard 24 V DC input module without overloading it. Each channel is limited to 0.008 A, and the PLC end has an internal 1 A fast-blow fuse (5 x 20 mm) for protection. An external fast-blow fuse on the sensor end is adjustable per the installation. Compliance with IEC 61131-2 Type 1 means the inputs are designed for 3-wire proximity sensors and similar devices, with defined thresholds for state 0 and state 1. Pollution degree 2 (IEC 60664-1) and installation category II suit it for clean, controlled environments like a panel interior, not for direct outdoor or wet-area mounting.","metaTitle":"Schneider Electric ABE7S16E2M0E Solid State Input Relay Sub-","metaDescription":"Obsolete Modicon ABE7 solid state input relay sub-base. 16 inputs, 230 V AC sensor end, 24 V DC PLC end. IEC 61131-2 Type 1. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC Accessories"],"specifications":{"Standards":"IEC 61131-2 Type 1","Fixing mode":"By clips (35 mm symmetrical DIN rail) By screws (solid plate with fixing kit)","Response time":"<= 20 ms from state 1 to 0","Protection type":"Internal fuse 1 A 5 x 20 mm fast blow PLC end Adjustable by external fuse fast blow sensor end","lifecycle_stage":"mature","Pollution degree":"2 conforming to IEC 60664-1","Range of product":"Modicon ABE7","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Tightening torque":"0.6 N.m with flat Ø 3.5 mm screwdriver","Number of channels":"16","Current per channel":"0.008 A","Dielectric strength":"2000 V at 50/60 Hz conforming to IEC 60947-1","Switching frequency":"<= 25 Hz duty cycle: 50 %","Terminal block type":"Removable","Maximum voltage drop":"<1 V at state 1 PLC end","Vibration resistance":"2 gn (f= 10...150 Hz) conforming to IEC 60068-2-6","Installation category":"II conforming to IEC 60664-1","Supply voltage limits":"19...30 V DC (PLC end) conforming to IEC 61131-2 264 V AC (sensor end) conforming to IEC 61131-2","Connections - terminals":"Spring terminal, 1 x 0.09...1 x 1.5 mm² (AWG 28...AWG 16) flexible with cable end Spring terminal, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 12) solid Spring terminal, 1 x 0.14...1 x 2.5 mm² (AWG 26...AWG 14) flexible without cable end","IP degree of protection":"IP2X conforming to IEC 60529","Maximum residual current":"0.1 mA at state 0 (PLC end)","Maximum switching current":"15 mA (PLC end)","Minimum switching current":"1 mA for PLC end","Product or component type":"Solid state input relay sub-base","[Us] rated supply voltage":"24 V DC (PLC end) 230/240 V AC 50/60 Hz (sensor end)","Current state 0 guaranteed":"= 4.5 mA (sensor end)","Voltage state 1 guaranteed":">= 164 V for sensor end","Isolation PLC/operative part":"Yes","Resistance to fast transients":"2 kV level 3 conforming to IEC 61000-4-4","Resistance to radiated fields":"10 V/m (26000000...1000000000 Hz) conforming to IEC 61000-4-3 level 3","[Ui] rated insulation voltage":"2000 V","Number of terminal per channel":"2","Resistance to incandescent wire":"750 °C, extinction time <30 s conforming to IEC 60695-2-11","Ambient air temperature for storage":"-40...80 °C conforming to IEC 61131-2","Ambient air temperature for operation":"-5...60 °C conforming to IEC 61131-2","Resistance to electrostatic discharge":"4 kV (contact) level 3 conforming to IEC 61000-4-2 8 kV (air) level 3 conforming to IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"2.5 kV conforming to IEC 60947-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/ABE7S16E2M0E/subbase-soldered-solid-state-output-relay-abe7-16-inputs-230-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ABE7S16E2M0E/alternatives.json"},"ai":{"faq":[{"question":"What are the mounting options for this sub-base?","answer":"It mounts on a 35 mm symmetrical DIN rail using the built-in clips, or on a solid plate using a separate fixing kit. This gives flexibility for panel integration."},{"question":"What standards does the ABE7S16E2M0E comply with?","answer":"It complies with IEC 61131-2 Type 1 for input characteristics, IEC 60664-1 for pollution degree 2 and installation category II, and IEC 60947-1 for dielectric and impulse withstand. It also meets IEC 60068-2-27 for shock and IEC 60068-2-6 for vibration."},{"question":"How do I source this obsolete part?","answer":"Since it is obsolete, it is sourced through surplus or broker channels. Submit an RFQ for a quote on available inventory — no stock is held on the shelf."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ABE7S16E2M0E","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ABE7S16E2M0E when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}