{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ABL6TS63U","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ABL6TS63U","canonicalUrl":"https://aoctrl.com/schneider/ABL6TS63U","factsUrl":"https://aoctrl.com/api/mcp/products/ABL6TS63U","rawCanonicalId":null},"summary":{"shortDescription":"Voltage Transformer","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"5.7 in (144.0 mm)","Width":"5.9 in (150.0 mm)","Height":"5.1 in (130.0 mm)","Marking":"CE","Category":"US1CP1018403","Standards":"UL 506","Efficiency":"93 %","Fixing mode":"By 4 screws 0.3 in (7 mm) vertical panel horizontal By 4 screws 0.3 in (7 mm) vertical panel vertical By 4 screws 0.3 in (7 mm) horizontal panel with derating to 90 %","Input voltage":"230 V AC single phase N-L1 400 V AC phase to phase L1-L2","No load losses":"18.9 W","Output voltage":"230 V AC","lifecycle_stage":"mature","Protective cover":"Without","Range of Product":"Modicon Transformer Optimized","Secondary winding":"Single","rated power in VA":"630 VA","Operating altitude":"9842.52 ft (3000 m)","Dielectric strength":"2000 V between winding and ground 4000 V between primary and secondary","Input voltage limits":"360...440 V 207...253 V","Overvoltage category":"Class I conforming to VDE 0106-1","Protective treatment":"TC","Nbr. of units in pkg.":"1","Short-circuit voltage":"0,0368","Output protection type":"Against overload, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection Against overvoltage, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection Against short-circuits, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection","Power dissipation in W":"47.4 W","Connections - terminals":"For input connection: screw type terminals, connection capacity: 5 x 4 mm² AWG 11 For input ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 11 For output connection: screw type terminals, connection capacity: 2 x 4 mm² AWG 11","IP Degree of Protection":"IP20","Input voltage tolerance":"+/- 15 V","Network frequency limits":"47...63 Hz","Product or Component Type":"Safety and isolation transformer","Electrical Insulation Class":"Class B","Environmental characteristic":"EMC conforming to IEC 62041 Safety conforming to EN 61558-1 Safety conforming to EN 61558-2-4","Output sustained overvoltage":"3 % no load, hot state)","Maximum voltage drop at rated load":"0.4 %","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient Air Temperature for Operation":"-4...122 °F (-20...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$238.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe07af3e315d5423c041ff5ea6968698.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ABL6TS63U/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ABL6TS63U","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ABL6TS63U when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}