{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ABLM1A12021","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ABLM1A12021","canonicalUrl":"https://aoctrl.com/schneider/ABLM1A12021","factsUrl":"https://aoctrl.com/api/mcp/products/ABLM1A12021","rawCanonicalId":null},"summary":{"shortDescription":"REGULATED POWER SUPPLY 100-240V AC 12V 2.1 A SINGL|REGULATED POWER SUPPLY 100-240V AC 12V 2.1 A SINGLE PHASE MODULAR","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"2.2 in (55.6 mm)","Width":"1.4 in (36 mm)","Height":"3.6 in (91 mm)","Supply":"SELV IEC 60950-1 SELV IEC 60204-1 SELV IEC 60364-4-41","Category":"US1CP1222525","Standards":"IEC 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201","Efficiency":"85 % 115 V AC 85 % 230 V AC","Status LED":"1 LED (Green) output voltage","Holding time":"> 20 ms 115 V AC > 60 ms 230 V AC","Power factor":"0.48 at 115 V AC 0.38 at 230 V AC","Service life":"10 year(s)","Turn-on time":"< 2 s","Inrush current":"25 A 115 V 50 A 230 V","Output voltage":"12 V DC","Variant option":"Modular","Output coupling":"Serial","Residual ripple":"< 100 mV","lifecycle_stage":"mature","Mounting support":"Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 Double-profile DIN rail panel mounting","Pollution degree":"2","Range of Product":"Modicon Power Supply","Rated power in W":"25 W","Shock resistance":"150 m/s² 11 ms","Power supply type":"Regulated switch mode","Enclosure Material":"Plastic","Operating altitude":"< 6561.68 ft (2000 m) overvoltage category III 2000 m...5000 m overvoltage category II","Current consumption":"< 0.8 A 115 V AC < 0.6 A 230 V AC","Dielectric strength":"3000 V AC input/output","Overvoltage category":"II","Vibration resistance":"3 mm (f= 2...9 Hz) conforming to IEC 60721-3-3 10 m/s² (f= 9...200 Hz) conforming to IEC 60721-3-3","Input protection type":"Integrated fuse (not interchangeable) 3.15 A External protection (recommended) 20 A Curve B External protection (recommended) 20 A Curve C External protection (recommended) 4 A Curve B External protection (recommended) 4 A Curve C","Nbr. of units in pkg.":"1","Nominal input voltage":"100...240 V AC single phase 100...240 V AC phase to phase","Output protection type":"Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset","Power dissipation in W":"4.6 W","Connections - terminals":"Screw connection 0.5...1.5 mm², AWG 20...AWG 16) without wire end ferrule input/output Screw connection 0.5...1 mm², AWG 20...AWG 18) with wire end ferrule input/output","Efficiency at full load":"90...264 V AC","IP degree of protection":"IP20","Maximum leakage current":"0.25 mA 240 V AC","Electromagnetic emission":"Conducted emissions IEC 61000-6-3 Radiated emissions IEC 61000-6-4","Electromagnetic immunity":"Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 Electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 Electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 Electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 Immunity to conducted disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 Immunity to voltage dips - test level: 100 % (1 cycle) conforming to IEC 61000-4-11 Immunity to voltage dips - test level: 60 % (10 cycles) conforming to IEC 61000-4-11 Immunity to voltage dips - test level: 30 % (25 cycles) conforming to IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to IEC 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1","Line and load regulation":"< 0.5 % network in line < 1 % network 0 to 100 % load","Nominal network frequency":"50...60 Hz","Output voltage adjustment":"12...15 V","Product or Component Type":"Power supply","Power supply output current":"2.1 A","Network system compatibility":"TN TT IT","Startup with capacitive loads":"3000 µF","Meantime between failure [MTBF]":"2500000 h at 77 °F (25 °C), full load 1000000 h at 131 °F (55 °C), 80 % load","Electrical shock protection class":"Class II without PE connection","Ambient air temperature for operation":"-13...131 °F (-25...55 °C) without current derating mounting position A < 6561.68 ft (2000 m) 131...158 °F (55...70 °C) with current derating of 2.67 % per °C mounting position A < 6561.68 ft (2000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$124.78","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/457939eaf1329a7a563d1e6a7ef52ba4.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ABLM1A12021/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ABLM1A12021","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ABLM1A12021 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}