{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ABLP1A12085","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ABLP1A12085","canonicalUrl":"https://aoctrl.com/schneider/ABLP1A12085","factsUrl":"https://aoctrl.com/api/mcp/products/ABLP1A12085","rawCanonicalId":null},"summary":{"shortDescription":"DIN Rail Power Supply 88% 12V 8.5A 100W Adjustable IP10 ABLP1","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"5.08 in (129 mm)","Width":"3.8 in (97 mm)","Height":"1.2 in (30 mm)","Supply":"SELV IEC 60950-1 SELV IEC 60204-1 SELV IEC 60364-4-41","Category":"US1CP1222524","Standards":"IEC 62368-1 IEC 61010-1 EN 61010-2-201 EN 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201","Efficiency":"88 % 230 V AC","Status LED":"1 LED (Green) output voltage","Holding time":"> 20 ms 115 V AC > 40 ms 230 V AC","Power factor":"0.55 at 115 V AC 0.45 at 230 V AC","Service life":"10 year(s)","Turn-on time":"< 500 ms","Inrush current":"45 A 115 V 85 A 230 V","Output voltage":"12 V DC","Variant option":"Panel mount","Output coupling":"Parallel Serial","Residual ripple":"< 120 mV","lifecycle_stage":"mature","Mounting support":"Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 Double-profile DIN rail panel mounting","Pollution degree":"2","Range of Product":"Modicon Power Supply","Rated power in W":"100 W","Shock resistance":"150 m/s² 11 ms","Power supply type":"Regulated switch mode","Enclosure Material":"Aluminum","Operating altitude":"5000 m","Current consumption":"< 2.3 A 115 V AC < 1.5 A 230 V AC","Dielectric strength":"3750 V AC with input to output","Overvoltage category":"II","Vibration resistance":"3 mm (f= 2...9 Hz) conforming to IEC 60068-2-6 10 m/s² (f= 9...200 Hz) conforming to IEC 60068-2-6","Input protection type":"Integrated fuse (not interchangeable) 4 A","Nbr. of units in pkg.":"1","Nominal input voltage":"100...240 V AC single phase","Output protection type":"Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset","Power dissipation in W":"21 W","Connections - terminals":"Screw connection 0.75...2.5 mm², AWG 18...AWG 14) without wire end ferrule Screw connection 0.75...1.5 mm², AWG 18...AWG 16) with wire end ferrule","Efficiency at full load":"90...264 V AC","IP degree of protection":"IP10","Maximum leakage current":"1 mA 240 V AC","Electromagnetic emission":"Conducted emissions IEC 61000-6-3 Radiated emissions IEC 61000-6-4","Electromagnetic immunity":"Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 Immunity to voltage dips conforming to IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to IEC 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1","Line and load regulation":"< 0.5 % network 0 to 100 % load at 77 °F (25 °C) < 1 % network full voltage range in line at 77 °F (25 °C)","Nominal network frequency":"50...60 Hz","Output voltage adjustment":"10.8...13.2 V","Product or Component Type":"Power supply","Power supply output current":"8.5 A","Network system compatibility":"TN TT IT","Startup with capacitive loads":"4000 µF","Meantime between failure [MTBF]":"700000 h at 77 °F (25 °C), full load conforming to SR 332","Electrical shock protection class":"Class I","Ambient air temperature for operation":"-22...122 °F (-30...50 °C) without derating mounting position A, B, F, G < 6561.68 ft (2000 m) 122...158 °F (50...70 °C) with current derating of 2 % per °C mounting position A, B, F, G < 6561.68 ft (2000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.37 – $103.72","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/78834566e051eea86b0816689b4365fa.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ABLP1A12085/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ABLP1A12085","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ABLP1A12085 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}