{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ABT7PDU010B","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ABT7PDU010B","canonicalUrl":"https://aoctrl.com/schneider/ABT7PDU010B","factsUrl":"https://aoctrl.com/api/mcp/products/ABT7PDU010B","rawCanonicalId":null},"summary":{"shortDescription":"voltage transformer - 230..400 V - 2 x 24 V - 100 VA","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["PLC"],"specifications":{"Depth":"138.0 mm","Width":"87.0 mm","Height":"108.0 mm","Marking":"CE","Standards":"UL 506","Efficiency":"86 %","Status LED":"1 LED (orange) input voltage","Fixing mode":"By 4 screws diameter: 5.5 mm on vertical panel, operating position: horizontal By 4 screws diameter: 5.5 mm on vertical panel, operating position: vertical By clips on 35 x 15 mm symmetrical DIN rail By 4 screws diameter: 5.5 mm on horizontal panel with derating to 90 %","Input voltage":"230 V AC single phase, terminal(s): N-L1 400 V AC phase to phase, terminal(s): L1-L2","No load losses":"10.69 W","Output voltage":"24/48 V AC","Output coupling":"Series by internal jumper Parallel Grounding of secondary","lifecycle_stage":"unknown","Protective cover":"With","Range of product":"Modicon Transformer Universal","Relative humidity":"0...95 % during operation","Secondary winding":"Double","rated power in VA":"100 VA","Operating altitude":"3000 m","Dielectric strength":"3200 V between input and ground 3200 V between output and ground 5100 V between input and output","Input voltage limits":"207...253 V 360...440 V","Overvoltage category":"Class I conforming to VDE 0106-1","Short-circuit voltage":"0,066","Output protection type":"Against overload, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection Against overvoltage, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection Against short-circuits, protection technology: with additional protection fuses or circuit-breakers in Selection of Protection","Power dissipation in W":"16.3 W","Connections - terminals":"For input connection: screw type terminals, connection capacity: 5 x 4 mm² AWG 11 For input ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 11 For output connection: screw type terminals, connection capacity: 4 x 4 mm² AWG 11","IP degree of protection":"IP20","Input voltage tolerance":"+/- 15 V","Network frequency limits":"47...63 Hz","Product or component type":"Safety and isolation transformer","Electrical insulation class":"Class B","Environmental characteristic":"EMC conforming to IEC 62041 Safety conforming to EN 61558-1 Safety conforming to EN 61558-2-6","Output sustained overvoltage":"0,026 (no load, hot state)","Voltage variation at nominal load":"0,0404 at 230 V 0,0429 at 400 V","Maximum voltage drop at rated load":"3.63 %","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/za/en/product/ABT7PDU010B/voltage-transformer-230-400-v-2-x-24-v-100-va/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ABT7PDU010B/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ABT7PDU010B","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ABT7PDU010B when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}