{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ACS355-03E-17A6-2","brand":"ABB","brandSlug":"abb","productSlug":"ACS355-03E-17A6-2","canonicalUrl":"https://aoctrl.com/abb/ACS355-03E-17A6-2","factsUrl":"https://aoctrl.com/api/mcp/products/ACS355-03E-17A6-2","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS355 series micro drive, ACS355-03E-17A6-2, 200 … 240 V three-phase input, 7.0 kV·A apparent output, R2 frame, IP20.","salesMarkdown":"## What the line item actually is The ABB ACS355-03E-17A6-2 is a micro drive from the ACS355 family in an R2 frame, built as a module for cabinet building and rated for a 200 … 240 V three-phase input at 50/60 Hz. Apparent power output is 7.0 kV·A, which is the figure an integrator uses to size the motor and the supply breaker for a BOM line — the drive sits at the small end of the ACS355 range, aimed at fractional-to-low-kW induction and permanent-magnet loads. ## Control I/O on the lid Control wiring lands on 2 analog inputs, 1 analog output, 5 digital inputs and 1 digital output — enough headroom for a typical sensor-plus-speed-pot cell, but tight if the line needs separate run-permit and fault-reset channels alongside a reference. Wiring is via the module's spring-cage style terminals; the drive mounts inside the cabinet on its R2 footprint, with a 166 mm × 344 mm × 217 mm envelope that leaves a 2.4 kg net weight to support on the backplate. ## Cabinet envelope and thermal limits Enclosure rating is IP20 Open Type, intended for installation inside a cabinet rather than wall-mounted in a wet area, and the drive is rated to a maximum ambient of 40 °C — derating kicks in above that, and the panel builder has to leave clearance around the R2 heat sink accordingly. Standby loss is 8 W and the drive meets IE2 efficiency class, which is the number that goes into tender scoring and into the panel's standby thermal budget, not the number that drives motor sizing. ## Application fit At 7.0 kV·A apparent output on a 200 … 240 V three-phase feed with 5 digital inputs and 1 digital output, this is the right box for low-horsepower constant- and variable-torque loads such as conveyors, small fans, pumps, and mixers. For long motor cable runs, watch reflected-wave overvoltage at the motor terminals — the cure is a dV/dt or sine filter at the drive output, sized to the cable length and the drive's switching frequency, not at the motor box.","metaTitle":"ABB ACS355-03E-17A6-2 drive, 7.0 kV·A, 200–240 V","metaDescription":"ABB ACS355-03E-17A6-2 micro drive, 200 … 240 V three-phase input, 7.0 kV·A apparent output, R2 frame, 2 AI / 1 AO / 5 DI / 1 DO. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ACS355-03E-17A6-2 - \"17\" MODEL WITH A6 TERMINAL STYLE AND -2 ENCLOSURE. by ASEA BROWN BOVERI","Weight":"2.4 kg","Net Width":"166 mm","Frame Size":"R2","Net Height":"344 mm","description":"ACS355-03E-17A6-2 - \"17\" MODEL WITH A6 TERMINAL STYLE AND -2 ENCLOSURE. by ASEA BROWN BOVERI","Standby Loss":"8 W","Analog Inputs":"2","Frequency (f)":"50/60 Hz","Mounting Type":"Module for cabinet building","Analog Outputs":"1","Shipping Weight":"3.5 Kg","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3","Net Depth / Length":"217 mm","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Estimated Lead Time":"1 - 10 Working Days","Input Voltage (Uin)":"200 … 240 V","Degree of Protection":"IP20","Apparent Power Output":"7.0 kV·A","Multiple Battery Information":"No battery / cell included","Number of Digital In/Outputs":"5/1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$856.00 – $1,160.83","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6316ac82cdab4e5515aa5928e7d368ff.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the drive's listed weight?","answer":"Net weight is 2.4 kg on this R2-frame ACS355, which is the figure a panel builder uses to plan mounting and shipping carton weight rather than motor sizing."},{"question":"What is the drive's net width for cabinet layout?","answer":"Net width is 166 mm on the R2 frame, with a 344 mm height and 217 mm depth — the envelope a wireman needs to clear inside the cabinet for airflow and cable bend radius."},{"question":"What supply and output ratings define this drive?","answer":"Input is 200 … 240 V three-phase at 50/60 Hz, with an apparent power output of 7.0 kV·A — the combination that fixes motor size and supply breaker selection on a BOM line."},{"question":"What I/O does the ACS355-03E-17A6-2 expose for control wiring?","answer":"The control surface is 2 analog inputs, 1 analog output, 5 digital inputs and 1 digital output — enough for a typical run/permit/fault channel set plus a process reference, tight if the cell needs extra I/O for a multi-step profile."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/ACS355-03E-17A6-2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/ACS355-03E-17A6-2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}