{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ACS550-PD-125A-4+C192","brand":"ABB","brandSlug":"abb","productSlug":"ACS550-PD-125A-4~3C192","canonicalUrl":"https://aoctrl.com/abb/ACS550-PD-125A-4~3C192","factsUrl":"https://aoctrl.com/api/mcp/products/ACS550-PD-125A-4%2BC192","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS550-PD-125A-4+C192 irrigation drive, ACS550 family, 3-phase supply 380 to 480 V AC, NEMA 3R pump panel, 75 Hp heavy duty / 100 Hp normal duty, 96 A heavy duty / 124 A normal duty output.","salesMarkdown":"## What shows up at the pad The ABB ACS550-PD-125A-4+C192 is not a bare ACS550 chassis module — it ships as a factory-built pump panel built around the ACS550 platform, listed in the ABB irrigation-drive family and wired for 480 V three-phase service. Supply side is 3-phase at 380 to 480 V AC; output is 3-phase to the motor. The supply window matches transformer secondaries commonly seen on irrigation services. ## Cabinet contents and what the integrator sees The enclosure is NEMA/UL 3R rated and listed as service-entrance rated, with the ABB Advanced Keypad mounted on the door. That combination means it can sit outdoors at the pump pad with the disconnect landed directly to the line side — no upstream disconnect cabinet needed. Front-of-door controls are 22 mm pilot devices: a 5k speed pot, a Hand/Off/Auto selector, and three pilot lights for drive ready, drive run, and drive fault. The HOA and the speed pot set day-to-day pump operation: manual run at the panel or auto run from a remote contact. Surge protection is fitted at the line side, a control power transformer with an extra 100 VA of capacity is included, and a condensation heater lives inside the cabinet. The heater is the giveaway that the panel is built to sit through cold, damp nights — without it the ACS550 control board would be the first thing to suffer condensation on a spring morning. Cabinet footprint is 49 in tall by 32.36 in wide by 22.88 in deep, with a unit weight of 330 lb. At that mass the panel is a two-person lift onto a wall bracket or pad, and the wall or pad must be rated for the load — not something to surface-mount on a wooden pump-house wall. ## Sourcing and supply posture ACS550-PD-125A-4+C192 carries the full ABB pump-panel option code — the +C192 suffix bundles the NEMA 3R enclosure, the HOA / speed-pot pilot devices, and the CPT / surge / heater set into a single orderable string. Specifying it that way keeps the BOM line to one part number instead of a kit.","metaTitle":"ABB ACS550-PD-125A-4+C192 Irrigation Drive, 480V 3-Ph, 75/10","metaDescription":"ABB ACS550-PD-125A-4+C192 NEMA 3R irrigation VFD, 380-480V AC 3-phase, 75 Hp heavy duty / 100 Hp normal duty (96/124 A), pump panel with HOA and surge protection. RFQ to source.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Type":"Irrigation Drive","Phase":"3","title":"75Hp, 100Hp, ACS550, VFD, N3R, PUMP PANEL|3-Phase Supply Voltage, 380 - 480V AC, NEMA 3R, Pump Panel Configuration, 3-Phase Output, Normal Duty: 100 Hp. Heavy Duty: 75 Hp. Normal Duty: 124 Amp. Heavy Duty: 96 Amp. H: 49\" W: 32.36\" D: 22.88\" Weight: 330Lbs., Includes Standard: NEMA/UL 3R Enclosure, ABB Advanced Keypad on Door, Service Entrance Rated, Lightning/Surge Protection, 22mm Pilot Devices (Including 5k Speed Pot, Hand/Off/Auto Selector Switch, Pilot Lights: Drive Ready, Drive Run, Drive Fault), CPT W/ Extra 100va, and Condensation Heater In The Cabinet.","Volts AC":"480","Horsepower":"75","description":"75Hp, 100Hp, ACS550, VFD, N3R, PUMP PANEL|3-Phase Supply Voltage, 380 - 480V AC, NEMA 3R, Pump Panel Configuration, 3-Phase Output, Normal Duty: 100 Hp. Heavy Duty: 75 Hp. Normal Duty: 124 Amp. Heavy Duty: 96 Amp. H: 49\" W: 32.36\" D: 22.88\" Weight: 330Lbs., Includes Standard: NEMA/UL 3R Enclosure, ABB Advanced Keypad on Door, Service Entrance Rated, Lightning/Surge Protection, 22mm Pilot Devices (Including 5k Speed Pot, Hand/Off/Auto Selector Switch, Pilot Lights: Drive Ready, Drive Run, Drive Fault), CPT W/ Extra 100va, and Condensation Heater In The Cabinet.","Family / Style":"ACS550","lifecycle_stage":"eol_hot"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51c35cb14b7edab5a06d09f26d554d90.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the type listed for ACS550-PD-125A-4+C192?","answer":"The listed type is Irrigation Drive."},{"question":"What phase is ACS550-PD-125A-4+C192?","answer":"It is a 3-phase drive on both supply and output."},{"question":"What horsepower and current should I run the pump at?","answer":"The panel is dual-rated: 100 Hp / 124 A normal duty and 75 Hp / 96 A heavy duty. Continuous outdoor pump duty is typically run on the normal-duty curve; heavy-duty derating is used when the load profile demands it."},{"question":"What compliance markings does the panel carry?","answer":"The enclosure is NEMA/UL 3R rated and the panel is listed as service-entrance rated. Other compliance documents (RoHS, REACH, IEC variants) are not on the evidence sheet and would need to come from the ABB documentation pack at order entry."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/ACS550-PD-125A-4~3C192","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/ACS550-PD-125A-4~3C192 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}