{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ACS580-01-023A-4","brand":"ABB","brandSlug":"abb","productSlug":"ACS580-01-023A-4","canonicalUrl":"https://aoctrl.com/abb/ACS580-01-023A-4","factsUrl":"https://aoctrl.com/api/mcp/products/ACS580-01-023A-4","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580 series general-purpose variable frequency drive, 3-phase 480 V AC supply, 15 Hp normal duty / 10 Hp heavy duty, 23 A / 14 A output, wall-mount frame R2, order code ACS580-01-023A-4.","salesMarkdown":"The ABB ACS580-01-023A-4 is a general-purpose variable frequency drive in the ACS580 family, built as a wall-mount package for 3-phase 480 V AC supplies and rated 15 Hp in normal duty or 10 Hp in heavy duty. Output current tracks the duty class: 23 A on normal duty and 14 A on heavy duty — the duty selection, not the headline Hp number, is what determines whether a given motor fits on this frame. Frame R2 keeps the footprint at H 19.80\" x W 5.1\" x D 9.41\", so panel cutout and wall bracing are set before the field wiring run is even pulled. ## Reading the duty ratings Normal duty to 15 Hp at 23 A covers quadratic-torque loads — fans, pumps, centrifugal blowers — where the motor does not need to hold rated torque down to standstill. Heavy duty to 10 Hp at 14 A is the constant-torque envelope: conveyors, mixers, extruders, anything that can stall against the load and demands full torque at low speed. Specifying by Hp alone is the usual mistake on this frame — the 23 A / 14 A pair is what the motor protection actually keys off, so the BOM line should name the duty class alongside the Hp figure. ## Frame-mate within the ACS580-01 line On the same 480 V 3-phase R2 wall-mount platform, the closest listed alternative in the ACS580-01 family is the ACS580-01-014A-4 — same voltage, same phase, same 10 Hp class on the headline figure, and a drop-in for the same enclosure footprint. The ACS580-01-027A-4 (20 Hp) and ACS580-01-012A-4 (5 Hp) sit one frame class above and below respectively — both share the ACS580-01 series but move to a different physical frame, so neither is a same-cutout swap. ## Sourcing posture The ACS580-01-023A-4 is specified as a standard ACS580 family member in the ABB general-purpose drive line, sourced to order against the BOM — quote the exact order code on the RFQ so the duty class and frame are unambiguous at intake.","metaTitle":"ABB ACS580-01-023A-4 Drive, 480V 3PH, 15/10 Hp","metaDescription":"ABB ACS580-01-023A-4 general-purpose drive, 3-phase 480 V AC, 15 Hp normal duty / 10 Hp heavy duty (23 A / 14 A), wall-mount frame R2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Type":"General Purpose Drive","Phase":"3","title":"Variable Frequency Drive 3PH, 480V, 10/15Hp|3-Phase Supply Voltage, 380-480V AC, Wall Mount Drive, 3-Phase Output, Normal Duty: 15 Hp, Heavy Duty: 10 Hp, Normal Duty: 23 Amp, Heavy Duty: 14 Amp, Frame Size: R2: H: 19.80\" W: 5.1\" D: 9.41\"","Volts AC":"480","Horsepower":"10","description":"Variable Frequency Drive 3PH, 480V, 10/15Hp|3-Phase Supply Voltage, 380-480V AC, Wall Mount Drive, 3-Phase Output, Normal Duty: 15 Hp, Heavy Duty: 10 Hp, Normal Duty: 23 Amp, Heavy Duty: 14 Amp, Frame Size: R2: H: 19.80\" W: 5.1\" D: 9.41\"","Family / Style":"ACS580","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,831.31","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e633fa7327b5fdef29cb9038b00e8b68.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the closest functional second-source for the ACS580-01-023A-4?","answer":"Within the ACS580-01 line at 480 V 3-phase, the ACS580-01-014A-4 is the same voltage, same phase, same R2 wall-mount frame and matches the 10 Hp heavy-duty class — it is the natural cross-shop candidate on this footprint."},{"question":"Will the ACS580-01-023A-4 drop into a panel specified around the ACS580-01-014A-4 without rewiring?","answer":"Both units share the 480 V 3-phase R2 wall-mount envelope, so the enclosure cutout and gland plate land in the same place; the difference is the output envelope (15/10 Hp versus the 014A frame's lower Hp class), so the motor feeder and overload setting must be re-validated against the new duty current."},{"question":"What is the ACS580-01-023A-4 listed type on the Motor Drives line?","answer":"Listed type is General Purpose Drive, 3-phase, in the ABB ACS580 family."},{"question":"What is the ACS580-01-023A-4's phase?","answer":"3-phase."},{"question":"What compliance documentation does ABB provide for the ACS580-01-023A-4?","answer":"Compliance documentation (RoHS, REACH, UL, IEC) is not on the available record for this order code and should be requested with the RFQ against the specific ship-from / ship-to requirement."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/ACS580-01-023A-4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/ACS580-01-023A-4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}