{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ACS580-01-033A-4","brand":"ABB","brandSlug":"abb","productSlug":"ACS580-01-033A-4","canonicalUrl":"https://aoctrl.com/abb/ACS580-01-033A-4","factsUrl":"https://aoctrl.com/api/mcp/products/ACS580-01-033A-4","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01-033A-4 lower-voltage AC drive, three-phase 400-480 VAC input rated 21-25 A, heavy-duty 11 kW and light-duty 15 kW with 44.3 A maximum output current.","salesMarkdown":"## What the BOM line is actually buying The ABB ACS580-01-033A-4 is a lower-voltage AC drive in the ACS580-01 frame, fed from a 21-25 A three-phase 400-480 VAC 50/60 Hz supply, and it carries a heavy-duty rating of 11 kW, a light-duty rating of 15 kW, and a nominal rating of 15 kW with a 44.3 A maximum output current. The input current window 21-25 A is the first thing to fix in the spec — it sits inside the typical 400-480 VAC industrial feed and is what lines the drive up against branch protection and contactor sizing upstream. ## Reading the duty numbers correctly Two duty curves ride on the same frame: heavy-duty at 11 kW is the conservative number to use for constant-torque loads (conveyors, extruders, positive-displacement pumps), and light-duty at 15 kW applies to variable-torque loads (fans, centrifugal pumps) where the motor is not asked to deliver rated torque across the full speed range. The 44.3 A maximum output current is the ceiling the drive will hand the motor during peaks and during the current-limit region of the ramp — pick a motor whose full-load amps sit comfortably below that figure on the chosen duty curve, or the drive will fold back into current limit and the process ramps will stretch. ## Same-frame neighbours a buyer will weigh against it The next step up in the ACS580-01 line, ACS580-01-039A-4, keeps the same 11.8 kg mass and the same 22.9 x 20.3 x 49 cm cabinet footprint, but moves to heavy-duty 15 kW / light-duty 18.5 kW with a 56.9 A maximum output current — a real drop-in mechanical substitute when the process current demand grew after commissioning, not a different panel layout. The step down, ACS580-01-018A-4, is a different mechanical animal at 6.6 kg and a narrower 12.5 cm width on 47.3 cm height, rated heavy-duty 5.5 kW / light-duty 7.5 kW with a 22.7 A maximum output — it is a smaller frame and is not a panel-for-panel swap into a slot cut for the 033A. ## Cabinet layout — the numbers that actually drive the build At 22.9 cm deep, 20.3 cm wide and 49 cm tall, the ACS580-01-033A-4 is a tall, narrow module — the 49 cm vertical clearance is the dimension that decides the gland plate row and the wiring duct above the unit, not the 11.8 kg mass which a single installer can handle on a DIN or backplate lift.","metaTitle":"ABB ACS580-01-033A-4 drive, 15 kW / 44.3 A","metaDescription":"ABB ACS580-01-033A-4 lower-voltage AC drive, 21-25 A three-phase 400-480 VAC input, heavy-duty 11 kW / light-duty 15 kW, max output 44.3 A. Quoted against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ACS580-01-033A-4 - INPUT: 21-25 AMP 3 PHASE 400-480 VAC 50/60 HZ by ASEA BROWN BOVERI","Weight":"11.8 Kg","Product No":"ACS580-01-033A-4","description":"ACS580-01-033A-4 - INPUT: 21-25 AMP 3 PHASE 400-480 VAC 50/60 HZ by ASEA BROWN BOVERI","Product Type":"Lower Voltage AC Drives","Heavy-duty use":"11","Light-duty use":"15","Nominal ratings":"15","Shipping weight":"13 Kg","lifecycle_stage":"current","Estimated Lead Time":"1-10 Working Days..","Max. Output Current":"44.3","Dimensions (L x W x H)":"22.9cm cm x 20.3 cm x 49 cm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,012.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a5fba8574671d0b184f74b6a24ed56f9.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What input supply and current does the ACS580-01-033A-4 need?","answer":"Three-phase 400-480 VAC at 50/60 Hz, input current window 21-25 A, which is the figure to match against branch fusing and feeder sizing upstream."},{"question":"What are the heavy-duty and light-duty ratings of the ACS580-01-033A-4?","answer":"Heavy-duty 11 kW and light-duty 15 kW, with a nominal 15 kW rating and a 44.3 A maximum output current to the motor — pick the duty curve to match the load, not the headline kW number."},{"question":"Is the ACS580-01-039A-4 a drop-in replacement for the ACS580-01-033A-4?","answer":"Mechanically yes — same 11.8 kg mass and same 22.9 x 20.3 x 49 cm cabinet envelope — and it steps the drive up to heavy-duty 15 kW / light-duty 18.5 kW with a 56.9 A maximum output current when the process has grown past the 033A's rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/ACS580-01-033A-4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/ACS580-01-033A-4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}