{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ACS800-01-0120-7+E200+P901","brand":"ABB","brandSlug":"abb","productSlug":"ACS800-01-0120-7~3E200~3P901","canonicalUrl":"https://aoctrl.com/abb/ACS800-01-0120-7~3E200~3P901","factsUrl":"https://aoctrl.com/api/mcp/products/ACS800-01-0120-7%2BE200%2BP901","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS800-01-0120-7+E200+P901 wall-mount low-voltage AC drive in the ACS800-01 frame, option-coded +E200 +P901, listed at 36.29 kg for motor-drive duty.","salesMarkdown":"## What the order code carries The ABB ACS800-01-0120-7+E200+P901 is the exact option-coded build on the wall-mount ACS800-01 frame, not a generic catalogue line — the +E200 and +P901 suffixes are part of the order string and shape the as-shipped configuration alongside the 0120-7 rating slot. It sits in the ACS800-01 family of low-voltage AC drives, the compact wall-mount tier of that platform, and the suffix-coded structure is what makes this specific code a distinct BOM line rather than a family reference. Category placement is Motors & Motor Controls › Drives › Motor Drives, the path a cross-reference tool reads to locate the line. ## Cabinet-side reality at 36.29 kg Listed weight is 36.29 kg — a single-person lift on a stub wall or backplate is fine with a rated anchor pattern, but on a hot-strip mill stand where the drive lives close to the rolls it is the kind of mass that wants a reinforced panel section and the lifting eye the ACS800-01 frame ships with, not improvised rigging. Frame mass of 36.29 kg is also what governs the panel-builder's heat-sink clearance call: this is the compact wall-mount ACS800, so airflow above and below the heat-sink fins is the derating lever, and the cabinet thermal budget should be sized with that dissipation in mind rather than left to the nameplate alone. ## Where this class lives on the line Inside a hot-strip mill control room this is the drive class you'd specify for the stand auxiliaries that have to run immune to the EMI of the megawatt drives two cabinets over — a 0120-frame ACS800-01 with the right +E200 / +P901 coding fits that brief, and the suffix codes are where the EMC and environmental posture get locked in at order time. ## Cross-shop honesty DCS880-S02-0680-05X0 is a DC drive, not a same-function alternative to this AC drive — it does not belong on the same cross-shop shortlist. ACS880-01-156A-5 is the ACS880-01 platform, the successor family to ACS800-01 at the architecture level — not a coded drop-in for a +E200 +P901 string. ## Sourcing posture Brand line is ABB; the ACS800-01 platform has been progressively succeeded by the ACS880-01 family on new design-ins, which is the context a procurement officer is reading this against even when the record carries no per-MPN lifecycle date.","metaTitle":"ABB ACS800-01-0120-7+E200+P901 AC Drive, 36.29 kg","metaDescription":"ABB ACS800-01-0120-7+E200+P901 wall-mount AC drive (36.29 kg) with +E200 +P901 option coding, sourced to order against an RFQ for motor-drive spares.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drives (VFD)"],"specifications":{"Part #":"ACS800-01-0120-7+E200+P901","Weight":"36.29 kgs","Category":"Drives","Sub Category":"Motor Drives","Top Category":"Motors & Motor Controls","lifecycle_stage":"eol_hot"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ACS800-01-0120-7%2BE200%2BP901/alternatives.json"},"ai":{"faq":[{"question":"Will ACS800-01-0120-7+E200+P901 drop into a panel that was specified around ACS550-U1-059A-4+B055 without rewiring?","answer":"No. The two are different ABB drive platforms — ACS800-01 is the DTC, higher-performance tier and ACS550 is the general-purpose predecessor tier — so the control terminal map, parameter set, and option-code structure are not aligned. A swap from an ACS550-spec panel to this ACS800-01 build needs a control-terminal and parameter review, not just a mechanical refit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/ACS800-01-0120-7~3E200~3P901","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/ACS800-01-0120-7~3E200~3P901 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}