{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ACS800-104-0440-7","brand":"ABB","brandSlug":"abb","productSlug":"ACS800-104-0440-7","canonicalUrl":"https://aoctrl.com/abb/ACS800-104-0440-7","factsUrl":"https://aoctrl.com/api/mcp/products/ACS800-104-0440-7","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS800-104-0440-7 single drive module, frame R8i, heavy-duty rated 286 A at 270 kW, light-overload 367 A at 355 kW, continuous 382 A, 7 kW heat dissipation, 206 kg.","salesMarkdown":"## Reading the duty stack: which number actually switches the motor The ACS800-104-0440-7: Three ratings sit on the nameplate and each is a different question. Heavy-duty use is I_hd 286 A at P_hd 270 kW — the figure you size a constant-torque, high-inertia, or high-break load against. Light-overload use is I_N 367 A at P_N 355 kW — the variable-torque / light-overload profile. No-overload use is P_cont.max 355 kW with I_cont.max 382 A, and the peak the drive will hand you for short transients is I_max 571 A. Pick the curve by the load, not by the largest kilowatt figure on the page. Heat dissipation of 7 kW at full load is the dimensioning figure the panel OEM sizes the cabinet AC and the exhaust path on. Treat it as a heat source of that magnitude, not as a footnote — R8i is the frame where cooling design decides whether the drive derates in a hot enclosure.","metaTitle":"ABB ACS800-104-0440-7 single drive module, 270 kW HD","metaDescription":"ABB ACS800-104-0440-7 single drive module, frame R8i: 286 A / 270 kW heavy-duty, 367 A / 355 kW light-overload, 382 A continuous, 7 kW dissipation. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drives (VFD)"],"specifications":{"title":"Single drive module","Weight":"206 Kg","Frame size":"R8i","Product No.":"ACS800-104-0440-7","description":"Single drive module","Product Type":"Single drive module","Heavy-duty use":"I<sub>hd</sub> A : 286P<sub>hd</sub> kW : 270","I<sub>N</sub> A":"367","No-overload use":"P<sub>cont. max</sub> kW - 355","Nominal ratings":"I<sub>cont. max</sub> A : 382I<sub>max A</sub> : 571","lifecycle_stage":"eol_hot","I<sub>hd</sub> A":"286","P<sub>N</sub> kW":"355","I<sub>max A</sub>":"571","P<sub>hd</sub> kW":"270","Light-overload use":"I<sub>N</sub> A : 367P<sub>N</sub> kW : 355","Estimated Lead Time":"28 - 32 weeks.","Heat dissipation kW":"7","I<sub>cont. max</sub> A":"382"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f8218d53d95f53648921aa32f0c9864.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What frame size is the ACS800-104-0440-7?","answer":"R8i — the frame that decides cabinet footprint, gland plate, lifting kit and the cooling envelope around the heatsink."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/ACS800-104-0440-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/ACS800-104-0440-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}