{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"AF190-30-00-13","brand":"ABB","brandSlug":"abb","productSlug":"AF190-30-00-13","canonicalUrl":"https://aoctrl.com/abb/AF190-30-00-13","factsUrl":"https://aoctrl.com/api/mcp/products/AF190-30-00-13","rawCanonicalId":null},"summary":{"shortDescription":"ABB AF190-30-00-13, Non-Reversing, 3-pole, 156A, 100-250VAC/DC coil, current lifecycle.","salesMarkdown":"The ABB AF190-30-00-13 is a 3-pole non-reversing contactor rated at 156 A with a 100-250 VAC/DC coil. In a cement plant environment, that coil voltage range means it can be driven from the same control transformer feeding the PLC cabinet — no separate DC supply needed for the contactor logic. The 156 A rating handles the full-load current of a 75 kW mill motor or a preheater fan drive, but watch the AC-3 derating if you are switching squirrel-cage rotors directly; the AF190 frame carries the thermal capacity for repeated starts under load. The 156 A rating is the general-purpose (AC-1) resistive load current. For motor duty (AC-3), the AF190 frame typically derates to around 110-115 A — enough for a 55 kW motor at 400 V. The 100-250 VAC/DC coil is a wide-range electronic coil that holds in without a separate economizer circuit; it drops out cleanly below about 85 V, which gives you a predictable undervoltage release point. In a dusty MCC room, the sealed coil design avoids the carbon-track failures that plague economized AC coils on contactors that cycle every few minutes on a clinker crusher. ## Deployment Context It accepts standard ABB AF-series auxiliary contact blocks and mechanical interlocks for reversing pairs. The 3-pole configuration handles three-phase loads; for a reversing starter you need two units with a mechanical interlock kit. The coil terminals accept ring or fork lugs up to 6 mm², and the main power terminals take cable up to 95 mm² — sized for the 156 A feed from the MCC bus.","metaTitle":"ABB AF190-30-00-13 Non-Reversing Contactor, 156A","metaDescription":"ABB AF190-30-00-13 3-pole non-reversing contactor, 156A rated, 100-250VAC/DC coil. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Type":"Non-Reversing","title":"AF190-30-00-13","description":"ABB AF190-30-00-13 CTR,3P,156A,100-|*CTR 3P 156A 100-250VAC/DC","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$745.50","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6ac5e905c8c2e2a800e1f0e007ad825b.pdf","sourceUrl":null},"ai":{"faq":[{"question":"How do I get current pricing and availability for AF190-30-00-13?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest commercial terms."},{"question":"What is AF190-30-00-13's listed type on this component line?","answer":"The type is Non-Reversing, meaning it is a single-direction contactor. For reversing applications, two units plus a mechanical interlock are required."},{"question":"What is the closest pin-compatible alternative to AF190-30-00-13 in this component family?","answer":"Within the ABB AF family, the AF190-30-00-11 uses the same frame and coil voltage but with a different auxiliary contact configuration (1 NO + 1 NC versus 3 NO on the -13 variant). The -13 carries three normally-open main poles and no built-in auxiliaries; the -11 adds an auxiliary contact block. Both share identical mounting footprint, power terminal layout, and coil characteristics, so swapping between them requires only checking whether the aux contact count matches your control circuit."},{"question":"What compliance documentation does this brand provide for AF190-30-00-13?","answer":"ABB provides standard compliance documentation including CE declaration of conformity, RoHS and REACH statements, and UL/CSA file numbers for the AF contactor family. Specific certificates are available on request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/AF190-30-00-13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/AF190-30-00-13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}